2011Chinese Journal of Health Laboratory TechnologyRequires access

Determination of hexavalent chromium in water by Ion chromatography-mass spectrometry

Zhang Wen-gai

Open publisher page 0 citations

Abstract

Objective:A method for the determination of hexavalent chromium in water by ion chromatography-electrospray mass spectrometry was established.Methods: Sample was filtrated by a 0.22 μm micropore filter before injection.The separation of Cr(Ⅵ) was performed on a IonPac AS21 Analytical 2×250 mm column using solution of 20 mmol/L KOH as mobile phase,and the detection of Cr(Ⅵ) was carried out under selected ion monitoring(SIM) mode with monitoring ions of m/z118,117,101,85 and quantative ion of 117.Results: The calibration curve of Cr(Ⅵ) was linear in the range of 0 μg/L~100.0 μg/L with the method detection limit of 0.57 μg/L.The avarge recoveries(n=6) of Cr(Ⅵ) from blank samples spiked with three levels of 4.0 μg/L,10.0 μg/L,50.0 μg/L were 102%,101%,100% respectively,and the corresponding relative standard deviation were 1.27%,2.82% and1.63%.Comparing with the results by spectrophotometry,there was no significant difference.Conclusions: The method is simple,rapid,accurate and highly sensitive.

About this research paper

What this paper is about

Objective:A method for the determination of hexavalent chromium in water by ion chromatography-electrospray mass spectrometry was established.Methods: Sample was filtrated by a 0.22 μm micropore filter before injection.The separation of Cr(Ⅵ) was performed on a IonPac AS21 Analytical 2×250 mm column using solution of 20 mmol/L KOH as mobile phase,and the detection of Cr(Ⅵ) was carried out under selected ion monitoring(SIM) mode with monitoring ions of m/z118,117,101,85 and quantative ion of 117.Results: The calibration curve of Cr(Ⅵ) was linear in the range of 0 μg/L~100.0 μg/L with the method detection limit of 0.57 μg/L.The avarge recoveries(n=6) of Cr(Ⅵ) from blank samples spiked with three levels of 4.0 μg/L,10.0 μg/L,50.0 μg/L were 102%,101%,100% respectively,and the corresponding relative standard deviation were 1.27%,2.82% and1.63%.Comparing with the results by spectrophotometry,there was no significant difference.Conclusions: The method is simple,rapid,accurate and highly sensitive.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:A method for the determination of hexavalent chromium in water by ion chromatography-electrospray mass spectrometry was established.Methods: Sample was filtrated by a 0.22 μm micropore filter before injection.The separation of Cr(Ⅵ) was performed on a IonPac AS21 Analytical 2×250 mm column using solution of 20 mmol/L KOH as mobile phase,and the detection of Cr(Ⅵ) was carried out under selected ion monitoring(SIM) mode with monitoring ions of m/z118,117,101,85 and quantative ion of 117.Results: The calibration curve of Cr(Ⅵ) was linear in the range of 0 μg/L~100.0 μg/L with the method detection limit of 0.57 μg/L.The avarge recoveries(n=6) of Cr(Ⅵ) from blank samples spiked with three levels of 4.0 μg/L,10.0 μg/L,50.0 μg/L were 102%,101%,100% respectively,and the corresponding relative standard deviation were 1.27%,2.82% and1.63%.Comparing with the results by spectrophotometry,there was no significant difference.Conclusions: The method is simple,rapid,accurate and highly sensitive.

Key concepts: Detection limit, Chemistry, Chromatography, Calibration curve, Hexavalent chromium, Mass spectrometry, Chromium, Ion chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of hexavalent chromium in water by Ion chromatography-mass spectrometry — Research Paper | ScholarLens