2013Journal of Instrumental AnalysisRequires access

Determination of Hexavalent Chromium in Soil Sampres by Ultrasound-assisted Extraction Ion Chromatography

Zhang Ta

Open publisher page 0 citations

Abstract

An ultrasound-assisted ion chromatographic method was developed for the determinination of hexavalent chromium in the chromium contaminated sites.Using 0.3 mol/L KC1 solution as extractant,12 soil samples were treated by ultrasonic assisted extraction for 20 min.The sample was analyzed on a Metrosep A Supp 4-250(250 mm×4.0 mm) anion separation column,using a mixture of 4 mmol/L Na_2CO_3-1 mmol/L NaHCO_3 as eluent.The method showed a good linearity(r~2= 0.999 8) in the range of 0.01-20 mg/L for the hexavalent chromium.The detection limit was 0.003 mg/L,the spiked recoveries were in the range of 96.4%-106.8%with RSDs(n=3) of 0.56%.The method was simple,rapid and accurate,and was suitable for the investigation on the chromium contaminated sites.

About this research paper

What this paper is about

An ultrasound-assisted ion chromatographic method was developed for the determinination of hexavalent chromium in the chromium contaminated sites.Using 0.3 mol/L KC1 solution as extractant,12 soil samples were treated by ultrasonic assisted extraction for 20 min.The sample was analyzed on a Metrosep A Supp 4-250(250 mm×4.0 mm) anion separation column,using a mixture of 4 mmol/L Na_2CO_3-1 mmol/L NaHCO_3 as eluent.The method showed a good linearity(r~2= 0.999 8) in the range of 0.01-20 mg/L for the hexavalent chromium.The detection limit was 0.003 mg/L,the spiked recoveries were in the range of 96.4%-106.8%with RSDs(n=3) of 0.56%.The method was simple,rapid and accurate,and was suitable for the investigation on the chromium contaminated sites.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An ultrasound-assisted ion chromatographic method was developed for the determinination of hexavalent chromium in the chromium contaminated sites.Using 0.3 mol/L KC1 solution as extractant,12 soil samples were treated by ultrasonic assisted extraction for 20 min.The sample was analyzed on a Metrosep A Supp 4-250(250 mm×4.0 mm) anion separation column,using a mixture of 4 mmol/L Na_2CO_3-1 mmol/L NaHCO_3 as eluent.The method showed a good linearity(r~2= 0.999 8) in the range of 0.01-20 mg/L for the hexavalent chromium.The detection limit was 0.003 mg/L,the spiked recoveries were in the range of 96.4%-106.8%with RSDs(n=3) of 0.56%.The method was simple,rapid and accurate,and was suitable for the investigation on the chromium contaminated sites.

Key concepts: Chemistry, Hexavalent chromium, Chromium, Detection limit, Chromatography, Extraction (chemistry), Column chromatography, Ion chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Hexavalent Chromium in Soil Sampres by Ultrasound-assisted Extraction Ion Chromatography — Research Paper | ScholarLens