2015•Environmental Science SurveyRequires access

Determination of HCN in Air Using Flow Injection Analysis- Spectrophotometry

Fan Li-hu

Open publisher page 0 citations

Abstract

The HCN in air were tested by flow injection analysis. The results indicated that a good linearity was found in the range from 0. 000 mg / L to 0. 100 mg / L with a detection limit of 0. 36μg / L. The lowest detection concentration was 0. 00012 mg / m3 when sampling 30 liters of air. The relative standard deviation was 0. 7% ~ 2. 6%with the relative error of standard solution of 1. 8%. The relative deviation of the results obtained from flow injection analysis and isonicotinic acid- pyrazolone spectrophotometry was less than 8%. Therefore,the precision,accuracy and sensitivity of flow injection analysis were very high with low detection limit. Especially,this method is suitable to deal with the large quantities of samples.

About this research paper

What this paper is about

The HCN in air were tested by flow injection analysis. The results indicated that a good linearity was found in the range from 0. 000 mg / L to 0. 100 mg / L with a detection limit of 0. 36μg / L. The lowest detection concentration was 0. 00012 mg / m3 when sampling 30 liters of air. The relative standard deviation was 0. 7% ~ 2. 6%with the relative error of standard solution of 1. 8%. The relative deviation of the results obtained from flow injection analysis and isonicotinic acid- pyrazolone spectrophotometry was less than 8%. Therefore,the precision,accuracy and sensitivity of flow injection analysis were very high with low detection limit. Especially,this method is suitable to deal with the large quantities of samples.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The HCN in air were tested by flow injection analysis. The results indicated that a good linearity was found in the range from 0. 000 mg / L to 0. 100 mg / L with a detection limit of 0. 36μg / L. The lowest detection concentration was 0. 00012 mg / m3 when sampling 30 liters of air. The relative standard deviation was 0. 7% ~ 2. 6%with the relative error of standard solution of 1. 8%. The relative deviation of the results obtained from flow injection analysis and isonicotinic acid- pyrazolone spectrophotometry was less than 8%. Therefore,the precision,accuracy and sensitivity of flow injection analysis were very high with low detection limit. Especially,this method is suitable to deal with the large quantities of samples.

Key concepts: Detection limit, Relative standard deviation, Flow injection analysis, Spectrophotometry, Chemistry, Analytical Chemistry (journal), Chromatography, Standard deviation

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of HCN in Air Using Flow Injection Analysis- Spectrophotometry — Research Paper | ScholarLens