2012•Shanghai yufang yixueRequires access

The study of the method for determination of cyanide in water by flow injection analysis

Ding Yu

Open publisher page 0 citations

Abstract

[Objective] To establish a method for determination of cyanide in water by flow injection analysis(FIA).[Methods] Cyanide in water was detected by FIA,and the best experimental conditions were chosen.[Results] Under the best conditions,the linear range was 2.0-200.0 μg/L,and the detection limit of the method was 0.39 μg/L,with the relative standard deviations(RSD) of the determination of standard solution being 0.74%-3.19%.For analysis of water,this method obtained the satisfactory result,and the average recovery was 95.8%-106.1%.As compared with national standard methods as isonicotinic acid-barbituric acid spectrophotometry,flow injection analysis showed no significant difference in determination.[Conclusion] This method is sensitive and suitable for the determination of cyanide in water.

About this research paper

What this paper is about

[Objective] To establish a method for determination of cyanide in water by flow injection analysis(FIA).[Methods] Cyanide in water was detected by FIA,and the best experimental conditions were chosen.[Results] Under the best conditions,the linear range was 2.0-200.0 μg/L,and the detection limit of the method was 0.39 μg/L,with the relative standard deviations(RSD) of the determination of standard solution being 0.74%-3.19%.For analysis of water,this method obtained the satisfactory result,and the average recovery was 95.8%-106.1%.As compared with national standard methods as isonicotinic acid-barbituric acid spectrophotometry,flow injection analysis showed no significant difference in determination.[Conclusion] This method is sensitive and suitable for the determination of cyanide in water.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

[Objective] To establish a method for determination of cyanide in water by flow injection analysis(FIA).[Methods] Cyanide in water was detected by FIA,and the best experimental conditions were chosen.[Results] Under the best conditions,the linear range was 2.0-200.0 μg/L,and the detection limit of the method was 0.39 μg/L,with the relative standard deviations(RSD) of the determination of standard solution being 0.74%-3.19%.For analysis of water,this method obtained the satisfactory result,and the average recovery was 95.8%-106.1%.As compared with national standard methods as isonicotinic acid-barbituric acid spectrophotometry,flow injection analysis showed no significant difference in determination.[Conclusion] This method is sensitive and suitable for the determination of cyanide in water.

Key concepts: Cyanide, Flow injection analysis, Detection limit, Chemistry, Spectrophotometry, Linear range, Chromatography, Standard addition