2000Journal of Instrumental AnalysisRequires access

Determination of Formate, Acetate and Oxalate in Environmental Samples by Ion Chromatography

Lin Yan

Open publisher page 0 citations

Abstract

A method for the determination of formate, acetate and oxalate in environmental samples by ion chromatography is described. The result showed that the detection limits of the method for formate, acetate and oxalate were 0.02 mg/L, 0.10 mg/L and 0.04 mg/L; recoveries were 93%~106%, 94%~108% and 92%~109%; the RSDs were 1.2%, 2.4% and 2.7%; the linear ranges were 0.00~30 mg/L, 0.00~30 mg/L and 0.00~50 mg/L. The method is simple, rapid and reliable for determining formate, acetate and oxalate in rain, exhaust gas, surface water and ground water.

About this research paper

What this paper is about

A method for the determination of formate, acetate and oxalate in environmental samples by ion chromatography is described. The result showed that the detection limits of the method for formate, acetate and oxalate were 0.02 mg/L, 0.10 mg/L and 0.04 mg/L; recoveries were 93%~106%, 94%~108% and 92%~109%; the RSDs were 1.2%, 2.4% and 2.7%; the linear ranges were 0.00~30 mg/L, 0.00~30 mg/L and 0.00~50 mg/L. The method is simple, rapid and reliable for determining formate, acetate and oxalate in rain, exhaust gas, surface water and ground water.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method for the determination of formate, acetate and oxalate in environmental samples by ion chromatography is described. The result showed that the detection limits of the method for formate, acetate and oxalate were 0.02 mg/L, 0.10 mg/L and 0.04 mg/L; recoveries were 93%~106%, 94%~108% and 92%~109%; the RSDs were 1.2%, 2.4% and 2.7%; the linear ranges were 0.00~30 mg/L, 0.00~30 mg/L and 0.00~50 mg/L. The method is simple, rapid and reliable for determining formate, acetate and oxalate in rain, exhaust gas, surface water and ground water.

Key concepts: Chemistry, Oxalate, Formate, Chromatography, Ion chromatography, Methyl formate, Sodium formate, Inorganic chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Formate, Acetate and Oxalate in Environmental Samples by Ion Chromatography — Research Paper | ScholarLens