Biases and interlaboratory variations of gamma-glutamyltransferase measurements before and after calibration with a common human serum calibrator
Huimin Jia
Abstract
Huimin Jia
Abstract
Objective To investigate the accuracy and comparability of γ-glutamyltransferase (γ- GT) measurement results on human serum samples and controI materials before and after calibration with a common human serum calibrator.Methods A human serum calibrator was prepared by pooling fresh serum aliquots and assigning a value for γ-GT with the IFCC reference method.The calibrator together with 5 human serum samples and 10 control samples were sent to 15 clinical laboratories and the sermn and control samples were measured with different analytical systems before and after a calibration with the calibrator.The results were analyzed for biases and interlaboratory variations.Results For the serum samples,the calibration resulted in reductions in biases from -9.0%~-14.2% to -0.8%~-7.9%,and in interlaboratory variations from 6.9%~11.6% to 2.8%~4.4%.No improvement was observed on the control samples.Conclusions Accuracy and comparability of serum γ-GT measurements can be improved by using a common human serum calibrator.Some control materials may not be commutable for human serum in γ-GT measurements.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To investigate the accuracy and comparability of γ-glutamyltransferase (γ- GT) measurement results on human serum samples and controI materials before and after calibration with a common human serum calibrator.Methods A human serum calibrator was prepared by pooling fresh serum aliquots and assigning a value for γ-GT with the IFCC reference method.The calibrator together with 5 human serum samples and 10 control samples were sent to 15 clinical laboratories and the sermn and control samples were measured with different analytical systems before and after a calibration with the calibrator.The results were analyzed for biases and interlaboratory variations.Results For the serum samples,the calibration resulted in reductions in biases from -9.0%~-14.2% to -0.8%~-7.9%,and in interlaboratory variations from 6.9%~11.6% to 2.8%~4.4%.No improvement was observed on the control samples.Conclusions Accuracy and comparability of serum γ-GT measurements can be improved by using a common human serum calibrator.Some control materials may not be commutable for human serum in γ-GT measurements.
Key concepts: Calibration, Comparability, Chromatography, Pooling, Human blood, Chemistry, Medicine, Mathematics