2007Journal of Yunnan Normal UniversityRequires access

Separation and Determination of Bensulfuron,Acetochlor in Herbicide by High Performance Liquid Chromatography

Xie Xiao-tian

Open publisher page 0 citations

Abstract

A method for the direct determination of bensulfuron,acetochlor in the composite herbicide by HPLC has been described.DIKMA-Diamonsil C18 column(250×4.6mm,5μm)was used with the mobile phase of methanol and water(80∶20,V/V),the wavelength was at 230nm,and the flow rate was 1.0mL/min.Linear regression coefficient was 0.9999,Quantification was carried out with the two external standards.The average recovery was 99.29% with RSD= 0.71% for bensulfuron,100.24% with RSD= 0.73% for.acetochlor.The method was accurate,rapid.and reproducible and can be used for the quality control for 20% bensulfuronacetochlor composite herbicide.

About this research paper

What this paper is about

A method for the direct determination of bensulfuron,acetochlor in the composite herbicide by HPLC has been described.DIKMA-Diamonsil C18 column(250×4.6mm,5μm)was used with the mobile phase of methanol and water(80∶20,V/V),the wavelength was at 230nm,and the flow rate was 1.0mL/min.Linear regression coefficient was 0.9999,Quantification was carried out with the two external standards.The average recovery was 99.29% with RSD= 0.71% for bensulfuron,100.24% with RSD= 0.73% for.acetochlor.The method was accurate,rapid.and reproducible and can be used for the quality control for 20% bensulfuronacetochlor composite herbicide.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method for the direct determination of bensulfuron,acetochlor in the composite herbicide by HPLC has been described.DIKMA-Diamonsil C18 column(250×4.6mm,5μm)was used with the mobile phase of methanol and water(80∶20,V/V),the wavelength was at 230nm,and the flow rate was 1.0mL/min.Linear regression coefficient was 0.9999,Quantification was carried out with the two external standards.The average recovery was 99.29% with RSD= 0.71% for bensulfuron,100.24% with RSD= 0.73% for.acetochlor.The method was accurate,rapid.and reproducible and can be used for the quality control for 20% bensulfuronacetochlor composite herbicide.

Key concepts: Acetochlor, Chromatography, High-performance liquid chromatography, Chemistry, Pesticide, Agronomy, Biology

Related papers

Back to paper searchBrowse research topicsOriginal source
Separation and Determination of Bensulfuron,Acetochlor in Herbicide by High Performance Liquid Chromatography — Research Paper | ScholarLens