2015•Chinese Journal of Analysis LaboratoryRequires access

Rapid determination of free formaldehyde in water-based coatings and adhesives by headspace-gas chromatography-mass spectrometry

Ma Min

Open publisher page 0 citations

Abstract

The method was developed for rapid determination of free formaldehyde in water-based coatings and adhesives by head space-gas chromatography-mass spectrometry.After the sample was completely dissolved in water,it was positioned to headspace sampling instrument and heated at 80 ℃ for 20 minutes for a distribution equilibrium of formaldehyde between gas and liquid phases.The headspace gas was extracted and injected into gas chromatograph for analysis with selective ion mode of mass spectrometry(MSD).Formaldehyde was separated from air and other interference substances by the capillary column of PLOT/Q.Retention time and fragment ions abundance ratio were used for qualitative analysis,and external standard method was applied to quantitation.The results showed that the linear range was 1.0 ~ 100.0 mg/L with the linear equation of y = 448.9777 x + 16.6253 and correlation coefficient of 0.9997.The detection limit was 5 mg/kg.The recoveries were 91.3% ~ 96.7% and relative standard deviations(RSDs)(n = 6) were 1.3% ~ 2.1%.This method is simple,rapid and repeatable,which is applicable for rapid analysis of free formaldehyde in water-based coatings and adhesives.

About this research paper

What this paper is about

The method was developed for rapid determination of free formaldehyde in water-based coatings and adhesives by head space-gas chromatography-mass spectrometry.After the sample was completely dissolved in water,it was positioned to headspace sampling instrument and heated at 80 ℃ for 20 minutes for a distribution equilibrium of formaldehyde between gas and liquid phases.The headspace gas was extracted and injected into gas chromatograph for analysis with selective ion mode of mass spectrometry(MSD).Formaldehyde was separated from air and other interference substances by the capillary column of PLOT/Q.Retention time and fragment ions abundance ratio were used for qualitative analysis,and external standard method was applied to quantitation.The results showed that the linear range was 1.0 ~ 100.0 mg/L with the linear equation of y = 448.9777 x + 16.6253 and correlation coefficient of 0.9997.The detection limit was 5 mg/kg.The recoveries were 91.3% ~ 96.7% and relative standard deviations(RSDs)(n = 6) were 1.3% ~ 2.1%.This method is simple,rapid and repeatable,which is applicable for rapid analysis of free formaldehyde in water-based coatings and adhesives.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The method was developed for rapid determination of free formaldehyde in water-based coatings and adhesives by head space-gas chromatography-mass spectrometry.After the sample was completely dissolved in water,it was positioned to headspace sampling instrument and heated at 80 ℃ for 20 minutes for a distribution equilibrium of formaldehyde between gas and liquid phases.The headspace gas was extracted and injected into gas chromatograph for analysis with selective ion mode of mass spectrometry(MSD).Formaldehyde was separated from air and other interference substances by the capillary column of PLOT/Q.Retention time and fragment ions abundance ratio were used for qualitative analysis,and external standard method was applied to quantitation.The results showed that the linear range was 1.0 ~ 100.0 mg/L with the linear equation of y = 448.9777 x + 16.6253 and correlation coefficient of 0.9997.The detection limit was 5 mg/kg.The recoveries were 91.3% ~ 96.7% and relative standard deviations(RSDs)(n = 6) were 1.3% ~ 2.1%.This method is simple,rapid and repeatable,which is applicable for rapid analysis of free formaldehyde in water-based coatings and adhesives.

Key concepts: Chemistry, Formaldehyde, Detection limit, Chromatography, Mass spectrometry, Gas chromatography, Analytical Chemistry (journal), Gas chromatography–mass spectrometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Rapid determination of free formaldehyde in water-based coatings and adhesives by headspace-gas chromatography-mass spectrometry — Research Paper | ScholarLens