2010•Hebei Journal of Industrial Science and TechnologyRequires access

Determination of acetaldehyde in ground water by auto headspace-gas chromatography

Baoyou Liu

Open publisher page 0 citations

Abstract

The determination method of acetaldehyde in ground water by auto headspace-gas chromatography was established.And the parameters of the headspace sampler such as vial pressuring time,loop temperature,loop equal time,sample loopfill time and vial temperature were optimized.The sensitivity and precisions of this method were tested.The result of the study shows that the method not only has better detection limit(0.012 mg/L),relative standard deviation(3.5%) and linear correlation coefficient(0.999 8) than manual headspace,but also improves the detection efficiency significantly.

About this research paper

What this paper is about

The determination method of acetaldehyde in ground water by auto headspace-gas chromatography was established.And the parameters of the headspace sampler such as vial pressuring time,loop temperature,loop equal time,sample loopfill time and vial temperature were optimized.The sensitivity and precisions of this method were tested.The result of the study shows that the method not only has better detection limit(0.012 mg/L),relative standard deviation(3.5%) and linear correlation coefficient(0.999 8) than manual headspace,but also improves the detection efficiency significantly.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The determination method of acetaldehyde in ground water by auto headspace-gas chromatography was established.And the parameters of the headspace sampler such as vial pressuring time,loop temperature,loop equal time,sample loopfill time and vial temperature were optimized.The sensitivity and precisions of this method were tested.The result of the study shows that the method not only has better detection limit(0.012 mg/L),relative standard deviation(3.5%) and linear correlation coefficient(0.999 8) than manual headspace,but also improves the detection efficiency significantly.

Key concepts: Acetaldehyde, Chromatography, Detection limit, Gas chromatography, Correlation coefficient, Chemistry, Relative standard deviation, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of acetaldehyde in ground water by auto headspace-gas chromatography — Research Paper | ScholarLens