Rapid Diagnostic Method of Stator Ground Fault Caused by a Faulty Terminal Capacitor
TU Xiaota
Abstract
TU Xiaota
Abstract
It is difficult to diagnose the stator ground fault caused by a faulty terminal capacitor with the help of detecting insulation resistance.The corresponding mechanism is analyzed first based on the equivalent circuit of stator ground fault.Three-phase reference composed of stator voltages is adopted to make a comparative analysis on the phase characteristics of zero sequence voltage,which can be used to discriminate the stator ground fault caused by a faulty terminal capacitor or grounding transient resistance.And a practical method is proposed based on the foregoing characteristics.In this approach,the position of zero sequence voltage in the three-phase reference can be judged by voltage waveforms from the wave-recording device.Furthermore,the winding capacitance to ground and grounding resistance of the neutral point should be utilized to realize rapid diagnosis.Finally,the effectiveness of the proposed approach is verified through a relevant fault example.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
It is difficult to diagnose the stator ground fault caused by a faulty terminal capacitor with the help of detecting insulation resistance.The corresponding mechanism is analyzed first based on the equivalent circuit of stator ground fault.Three-phase reference composed of stator voltages is adopted to make a comparative analysis on the phase characteristics of zero sequence voltage,which can be used to discriminate the stator ground fault caused by a faulty terminal capacitor or grounding transient resistance.And a practical method is proposed based on the foregoing characteristics.In this approach,the position of zero sequence voltage in the three-phase reference can be judged by voltage waveforms from the wave-recording device.Furthermore,the winding capacitance to ground and grounding resistance of the neutral point should be utilized to realize rapid diagnosis.Finally,the effectiveness of the proposed approach is verified through a relevant fault example.
Key concepts: Ground, Stator, Transient (computer programming), Terminal (telecommunication), Waveform, Fault (geology), Voltage, Capacitance