2013Dianli xitong zidonghuaRequires access

Location Method for Stator Single-phase Ground Fault Independent of Injection Type Principle

Shen Quanrong

Open publisher page 4 citations

Abstract

A new location method for stator single-phase ground fault of a generator is proposed,in which neutral-point of the generator is grounded via the distribution transformer secondary winding with a high resistor.It can be used as qualitative guidance for earth fault searching.The ground fault phase can be easily judged with the characteristic of generator three-phase terminal voltage after stator single-phase ground fault.Expressing generator three-phase terminal voltage with fault phase electric motive force,and through comparing three-phase voltage square difference,stator ground fault transient resistance and ground fault location can be calculated.The proposed method is simple and independent of voltage injection type stator ground fault protection,therefore,it is simple and easy to popularize.Actual recording data on site show that the method is correct.

About this research paper

What this paper is about

A new location method for stator single-phase ground fault of a generator is proposed,in which neutral-point of the generator is grounded via the distribution transformer secondary winding with a high resistor.It can be used as qualitative guidance for earth fault searching.The ground fault phase can be easily judged with the characteristic of generator three-phase terminal voltage after stator single-phase ground fault.Expressing generator three-phase terminal voltage with fault phase electric motive force,and through comparing three-phase voltage square difference,stator ground fault transient resistance and ground fault location can be calculated.The proposed method is simple and independent of voltage injection type stator ground fault protection,therefore,it is simple and easy to popularize.Actual recording data on site show that the method is correct.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new location method for stator single-phase ground fault of a generator is proposed,in which neutral-point of the generator is grounded via the distribution transformer secondary winding with a high resistor.It can be used as qualitative guidance for earth fault searching.The ground fault phase can be easily judged with the characteristic of generator three-phase terminal voltage after stator single-phase ground fault.Expressing generator three-phase terminal voltage with fault phase electric motive force,and through comparing three-phase voltage square difference,stator ground fault transient resistance and ground fault location can be calculated.The proposed method is simple and independent of voltage injection type stator ground fault protection,therefore,it is simple and easy to popularize.Actual recording data on site show that the method is correct.

Key concepts: Stator, Ground, Residual-current device, Generator (circuit theory), Engineering, Transient (computer programming), Resistor, Fault (geology)

Related papers

Back to paper searchBrowse research topicsOriginal source
Location Method for Stator Single-phase Ground Fault Independent of Injection Type Principle — Research Paper | ScholarLens