Clinical effects of the AC-IOL implantation.
Yang Gui-fan
Abstract
Yang Gui-fan
Abstract
Objective To observe the clinical effects and complications of flexible open-loop anterior chamber intraocular lens and evaluate its safety. Methods Sixteen AC-IOL implanted eyes were followed up postoper-atively for 1 to 18 months, their vision, corneal and intraocular pressure were observed.The operation was phacoemulsification combined with primary or secondary AC - IOL implantation. Results One week postopera-tively,the visual acuity of 18.8% eyey was 0.5, 68.8% was 0.1 ~ 0.5 and 12.5% was 0.1. There were corneal endothelial edema in 85.7% eyes with primary implantation and 44.4% eyes with secondary implantation. There were 68.8 % eyes with peripheral anterior synechia. There were 18.8% eyes with increased intraocular pressure. Conclusion The flexible open-loop anterior chamber intraocular lens implantation is easy to do. We can chose this method when without the posterior capsular support,but the long term effects and complications should be observed.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To observe the clinical effects and complications of flexible open-loop anterior chamber intraocular lens and evaluate its safety. Methods Sixteen AC-IOL implanted eyes were followed up postoper-atively for 1 to 18 months, their vision, corneal and intraocular pressure were observed.The operation was phacoemulsification combined with primary or secondary AC - IOL implantation. Results One week postopera-tively,the visual acuity of 18.8% eyey was 0.5, 68.8% was 0.1 ~ 0.5 and 12.5% was 0.1. There were corneal endothelial edema in 85.7% eyes with primary implantation and 44.4% eyes with secondary implantation. There were 68.8 % eyes with peripheral anterior synechia. There were 18.8% eyes with increased intraocular pressure. Conclusion The flexible open-loop anterior chamber intraocular lens implantation is easy to do. We can chose this method when without the posterior capsular support,but the long term effects and complications should be observed.
Key concepts: Synechia, Medicine, Phacoemulsification, Ophthalmology, Intraocular lens, Intraocular pressure, Visual acuity, Surgery