STUDY ON THE CLEANING EFFECT OF MEDICAL INSTRUMENT MONITORED BY NINHYDRIN REAGENT

Liubo Zhang

Open publisher page 0 citations

Abstract

Objective To evaluate the cleaning effect of medical instrument by ninhydrin reagent.Method Monitoring the cleaning effect of medical instrument by cotton swab smeared and dipped with ninhydrin reagent,which was compared with traditional naked eye observation,vision correction method and occult blood test.Results 5 μg,0.5 μg and 0.05 μg Glycine can be detected respectively by ninhydrin reagent at 37℃、54℃ and 110℃ for 30 min.0.5 μg Glycine can be detected by ninhydrin reagent at 37℃ for 60 min.The variation of color developing reaction was significant when pH changed from 6 to 8.Ninhydrin reagent method was more sensitive for detecting residue of organism on medical instrument than OB test,vision correction method and naked eye observation.Conclusion The sensitivity of ninhydrin reagent to evaluate the cleaning effect is better than that of OB test and naked eye observation,while it is influenced by temperature,pH and color developing time.

About this research paper

What this paper is about

Objective To evaluate the cleaning effect of medical instrument by ninhydrin reagent.Method Monitoring the cleaning effect of medical instrument by cotton swab smeared and dipped with ninhydrin reagent,which was compared with traditional naked eye observation,vision correction method and occult blood test.Results 5 μg,0.5 μg and 0.05 μg Glycine can be detected respectively by ninhydrin reagent at 37℃、54℃ and 110℃ for 30 min.0.5 μg Glycine can be detected by ninhydrin reagent at 37℃ for 60 min.The variation of color developing reaction was significant when pH changed from 6 to 8.Ninhydrin reagent method was more sensitive for detecting residue of organism on medical instrument than OB test,vision correction method and naked eye observation.Conclusion The sensitivity of ninhydrin reagent to evaluate the cleaning effect is better than that of OB test and naked eye observation,while it is influenced by temperature,pH and color developing time.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To evaluate the cleaning effect of medical instrument by ninhydrin reagent.Method Monitoring the cleaning effect of medical instrument by cotton swab smeared and dipped with ninhydrin reagent,which was compared with traditional naked eye observation,vision correction method and occult blood test.Results 5 μg,0.5 μg and 0.05 μg Glycine can be detected respectively by ninhydrin reagent at 37℃、54℃ and 110℃ for 30 min.0.5 μg Glycine can be detected by ninhydrin reagent at 37℃ for 60 min.The variation of color developing reaction was significant when pH changed from 6 to 8.Ninhydrin reagent method was more sensitive for detecting residue of organism on medical instrument than OB test,vision correction method and naked eye observation.Conclusion The sensitivity of ninhydrin reagent to evaluate the cleaning effect is better than that of OB test and naked eye observation,while it is influenced by temperature,pH and color developing time.

Key concepts: Ninhydrin, Reagent, Chemistry, Chromatography, Naked eye, Glycine, Biochemistry, Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
STUDY ON THE CLEANING EFFECT OF MEDICAL INSTRUMENT MONITORED BY NINHYDRIN REAGENT — Research Paper | ScholarLens