Determination of 4 Amino Acids Neurotransmitters in Rat Hippocampi by RP-HPLC
Fan Zhang
Abstract
Fan Zhang
Abstract
In this paper,a method for the determination of 4 amino acids neurotransmitters in rat hippocampi by RP-HPLC was established.The samples were precolumn derivated with DNFB.The chromatogram condition is Diamonsil C18 column(4.6mm×200mm,5μm).Acetonitrile/acetate buffer solution was used as mobile phase and the gradient elution was detected by UV at 350 nm.The results showed that 4 amino acids neurotransmitters were separated within 18 minutes.The linear relation was well in the range from 0.01 to 100μg/mL,and the correlation coefficients of Asp,Glu,Gly and GABA were 0.9985,0.9976,0.9943,and 0.9924,respectively.The coefficient of differentiations were 2.4%,3.8%,3.2% and 3.5%,and the average recoveries were 94.80%,93.93%,92.69%and 96.74%,respectively.This method is speediness,accurate,simple,high sensible and well repetition and provides a reference for the determination of amino acids neurotransmitter and related researches.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
In this paper,a method for the determination of 4 amino acids neurotransmitters in rat hippocampi by RP-HPLC was established.The samples were precolumn derivated with DNFB.The chromatogram condition is Diamonsil C18 column(4.6mm×200mm,5μm).Acetonitrile/acetate buffer solution was used as mobile phase and the gradient elution was detected by UV at 350 nm.The results showed that 4 amino acids neurotransmitters were separated within 18 minutes.The linear relation was well in the range from 0.01 to 100μg/mL,and the correlation coefficients of Asp,Glu,Gly and GABA were 0.9985,0.9976,0.9943,and 0.9924,respectively.The coefficient of differentiations were 2.4%,3.8%,3.2% and 3.5%,and the average recoveries were 94.80%,93.93%,92.69%and 96.74%,respectively.This method is speediness,accurate,simple,high sensible and well repetition and provides a reference for the determination of amino acids neurotransmitter and related researches.
Key concepts: Chromatography, High-performance liquid chromatography, Chemistry, Amino acid, Neurotransmitter, Gradient elution, Elution, Acetonitrile