Clinical study of left ventricular diastolic function in patients with heart disease by M-mode color Doppler echocardiography
Zhang Ruifang
Abstract
Zhang Ruifang
Abstract
Objective To evaluate the value and accuracy of M-mode color Doppler echocardiography for detecting left ventricular diastolic function in patients with cardiac disease. Methods The rate of left ventricular filling flow propagation (Vp) and the early -diastolic peak velocity of the mitral annulus(E) was measured in normal subjects(n=40)and in patients with cardiac disease (n=40). All the patients had abnormal left ventricular diastolic function confirmed by isotope-angiography test. Results ① The Vp was significantly lowered in patients with cardiac disease than in normal subjects(P 0.01).Furthermore, the Vp was significantly reduced in 12 patients with E/A≥1(pseudonormalized transmitral flow pattern); ②In 40 patients, the correlation between the Vp and PFR obtained by isotope-angiography test, and the correlation between Vp and E were good(r= 0.83, 0.80 respectively,P 0.01).Conclusions The Vp may provide an accurate method for evaluating left ventricular diastolic function and can identify the pseudonormalization of E/A.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To evaluate the value and accuracy of M-mode color Doppler echocardiography for detecting left ventricular diastolic function in patients with cardiac disease. Methods The rate of left ventricular filling flow propagation (Vp) and the early -diastolic peak velocity of the mitral annulus(E) was measured in normal subjects(n=40)and in patients with cardiac disease (n=40). All the patients had abnormal left ventricular diastolic function confirmed by isotope-angiography test. Results ① The Vp was significantly lowered in patients with cardiac disease than in normal subjects(P 0.01).Furthermore, the Vp was significantly reduced in 12 patients with E/A≥1(pseudonormalized transmitral flow pattern); ②In 40 patients, the correlation between the Vp and PFR obtained by isotope-angiography test, and the correlation between Vp and E were good(r= 0.83, 0.80 respectively,P 0.01).Conclusions The Vp may provide an accurate method for evaluating left ventricular diastolic function and can identify the pseudonormalization of E/A.
Key concepts: Medicine, Cardiology, Internal medicine, Diastole, Diastolic function, Doppler echocardiography, Color doppler, Ventricular function