2013•Metallurgical AnalysisRequires access

Determination of boron,silicon,tungsten and manganese in high niobium titanium aluminum alloy by inductively coupled plasma atomic emission spectrometry

Gao Son

Open publisher page 0 citations

Abstract

Determination of boron,silicon,tungsten and manganese in high niobium titanium aluminum alloy by inductively coupled plasma atomic emission spectrometry(ICP-AES)was achieved,with high-sensitivity spectral lines of boron,silicon,tungsten and manganese elements in high niobium titanium aluminum alloy as the analytical lines,with hydrochloric acid,hydrofluoric acid,nitric acid for dissolution of the sample,and the optimization of instrument working conditions.The low detection limits of the proposed method were 0.001μg/mL for B,0.002μg/mL for Si,W,0.000 1μg/mL for Mn,respectively.High niobium titanium aluminum alloy was used for addition recovery tests and the recoveries for the four elements were in the range of 95.2%-108%.The relative standard deviation of the sample determination results was less than 0.08 %.Titanium matrix reference materials were determined and the results were in line with the certified values.

About this research paper

What this paper is about

Determination of boron,silicon,tungsten and manganese in high niobium titanium aluminum alloy by inductively coupled plasma atomic emission spectrometry(ICP-AES)was achieved,with high-sensitivity spectral lines of boron,silicon,tungsten and manganese elements in high niobium titanium aluminum alloy as the analytical lines,with hydrochloric acid,hydrofluoric acid,nitric acid for dissolution of the sample,and the optimization of instrument working conditions.The low detection limits of the proposed method were 0.001μg/mL for B,0.002μg/mL for Si,W,0.000 1μg/mL for Mn,respectively.High niobium titanium aluminum alloy was used for addition recovery tests and the recoveries for the four elements were in the range of 95.2%-108%.The relative standard deviation of the sample determination results was less than 0.08 %.Titanium matrix reference materials were determined and the results were in line with the certified values.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Determination of boron,silicon,tungsten and manganese in high niobium titanium aluminum alloy by inductively coupled plasma atomic emission spectrometry(ICP-AES)was achieved,with high-sensitivity spectral lines of boron,silicon,tungsten and manganese elements in high niobium titanium aluminum alloy as the analytical lines,with hydrochloric acid,hydrofluoric acid,nitric acid for dissolution of the sample,and the optimization of instrument working conditions.The low detection limits of the proposed method were 0.001μg/mL for B,0.002μg/mL for Si,W,0.000 1μg/mL for Mn,respectively.High niobium titanium aluminum alloy was used for addition recovery tests and the recoveries for the four elements were in the range of 95.2%-108%.The relative standard deviation of the sample determination results was less than 0.08 %.Titanium matrix reference materials were determined and the results were in line with the certified values.

Key concepts: Niobium, Titanium, Inductively coupled plasma, Tungsten, Materials science, Hydrofluoric acid, Nitric acid, Silicon

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of boron,silicon,tungsten and manganese in high niobium titanium aluminum alloy by inductively coupled plasma atomic emission spectrometry — Research Paper | ScholarLens