2013Metallurgical AnalysisRequires access

Indirect determination of chlorine in chambersite by inductively coupled plasma atomic emission spectrometry

Xiangju Mao

Open publisher page 0 citations

Abstract

A novel method for indirect determination of chloride in chambersite by inductively coupled plasma atomic emission spectrometry(ICP-AES) was established.HNO3 was used to dissolve mineral samples and an extra amount of AgNO3 solution was added to the sample solution for the precipitation of AgCl.After the solution was transparent,remaining Ag in the solution was determined by inductively coupled plasma atomic emission spectrometry(ICP-AES) with spectral line of wavelength 328.068{102} nm as analysis line.By calculation,chloride in chambersite was indirectly determined.The experiment indicated the atomic emission strength of Ag had excellent linear relationship with ρ(Ag) in the range of 0-40 μg/mL.The method was used for determining chloride in chambersite,with recoveries of 98.8%-99.6% and RSD(n=6) of 0.11%-0.54%.

About this research paper

What this paper is about

A novel method for indirect determination of chloride in chambersite by inductively coupled plasma atomic emission spectrometry(ICP-AES) was established.HNO3 was used to dissolve mineral samples and an extra amount of AgNO3 solution was added to the sample solution for the precipitation of AgCl.After the solution was transparent,remaining Ag in the solution was determined by inductively coupled plasma atomic emission spectrometry(ICP-AES) with spectral line of wavelength 328.068{102} nm as analysis line.By calculation,chloride in chambersite was indirectly determined.The experiment indicated the atomic emission strength of Ag had excellent linear relationship with ρ(Ag) in the range of 0-40 μg/mL.The method was used for determining chloride in chambersite,with recoveries of 98.8%-99.6% and RSD(n=6) of 0.11%-0.54%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A novel method for indirect determination of chloride in chambersite by inductively coupled plasma atomic emission spectrometry(ICP-AES) was established.HNO3 was used to dissolve mineral samples and an extra amount of AgNO3 solution was added to the sample solution for the precipitation of AgCl.After the solution was transparent,remaining Ag in the solution was determined by inductively coupled plasma atomic emission spectrometry(ICP-AES) with spectral line of wavelength 328.068{102} nm as analysis line.By calculation,chloride in chambersite was indirectly determined.The experiment indicated the atomic emission strength of Ag had excellent linear relationship with ρ(Ag) in the range of 0-40 μg/mL.The method was used for determining chloride in chambersite,with recoveries of 98.8%-99.6% and RSD(n=6) of 0.11%-0.54%.

Key concepts: Inductively coupled plasma, Chemistry, Inductively coupled plasma atomic emission spectroscopy, Chlorine, Atomic emission spectroscopy, Analytical Chemistry (journal), Inductively coupled plasma mass spectrometry, Chloride

Related papers

Back to paper searchBrowse research topicsOriginal source
Indirect determination of chlorine in chambersite by inductively coupled plasma atomic emission spectrometry — Research Paper | ScholarLens