Design of high precision blood pressure meter system based on pressure sensor

Hu Ji

Open publisher page 0 citations

Abstract

Blood pressure is an important index which reflects human body and blood pressure monitoring plays an important role in clinical and medical care.Aiming at shortcomings of measurement precision is not high and stability is bad of traditional MCU design scheme,a high precision blood pressure meter is designed based on pressure sensor by means of effective combination of MSP430 MCU and ARM processor.Start from pulse wave feature points,using an improved threshold method can accurately detect valid pulse wave peak values in many pathological conditions,it overcomes shortcoming of not high accuracy of traditional threshold method in detecting pulse wave,and is simple and has short measuring time.Self-adaptive Kalman filtering algorithm is used to fit enveloping line which is better than Gaussian curve fitting and easy to implement programming.Test results show that the system error is lower than 4 mmHg and measurement range is 0 ~ 295 mmHg,and has advantages of high precision and fast speed.

About this research paper

What this paper is about

Blood pressure is an important index which reflects human body and blood pressure monitoring plays an important role in clinical and medical care.Aiming at shortcomings of measurement precision is not high and stability is bad of traditional MCU design scheme,a high precision blood pressure meter is designed based on pressure sensor by means of effective combination of MSP430 MCU and ARM processor.Start from pulse wave feature points,using an improved threshold method can accurately detect valid pulse wave peak values in many pathological conditions,it overcomes shortcoming of not high accuracy of traditional threshold method in detecting pulse wave,and is simple and has short measuring time.Self-adaptive Kalman filtering algorithm is used to fit enveloping line which is better than Gaussian curve fitting and easy to implement programming.Test results show that the system error is lower than 4 mmHg and measurement range is 0 ~ 295 mmHg,and has advantages of high precision and fast speed.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Blood pressure is an important index which reflects human body and blood pressure monitoring plays an important role in clinical and medical care.Aiming at shortcomings of measurement precision is not high and stability is bad of traditional MCU design scheme,a high precision blood pressure meter is designed based on pressure sensor by means of effective combination of MSP430 MCU and ARM processor.Start from pulse wave feature points,using an improved threshold method can accurately detect valid pulse wave peak values in many pathological conditions,it overcomes shortcoming of not high accuracy of traditional threshold method in detecting pulse wave,and is simple and has short measuring time.Self-adaptive Kalman filtering algorithm is used to fit enveloping line which is better than Gaussian curve fitting and easy to implement programming.Test results show that the system error is lower than 4 mmHg and measurement range is 0 ~ 295 mmHg,and has advantages of high precision and fast speed.

Key concepts: Microcontroller, Metre, Computer science, Kalman filter, Accuracy and precision, Pulse Wave Analysis, Pressure sensor, Gaussian

Related papers

Back to paper searchBrowse research topicsOriginal source
Design of high precision blood pressure meter system based on pressure sensor — Research Paper | ScholarLens