2013Electrotechnics ElectricRequires access

Analysis of 220 kV Main Transformer Protection Action Caused by Device Failure

Cai Sheng-zho

Open publisher page 0 citations

Abstract

Introduction was made to the two sets of main transformer fault tripping basic situation in certain 220 kV substation due to the equipment fault of direct power purchaser. Combined with the onsite equipment, this paper analyzed and explained the causes of main transformer protection action, raising the corresponding anti-accident measures. Requirements were made to strengthen user equipment supervision and to set down objective protection set value adjustment plan, which provides safe and stable operation for equipment.

About this research paper

What this paper is about

Introduction was made to the two sets of main transformer fault tripping basic situation in certain 220 kV substation due to the equipment fault of direct power purchaser. Combined with the onsite equipment, this paper analyzed and explained the causes of main transformer protection action, raising the corresponding anti-accident measures. Requirements were made to strengthen user equipment supervision and to set down objective protection set value adjustment plan, which provides safe and stable operation for equipment.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Introduction was made to the two sets of main transformer fault tripping basic situation in certain 220 kV substation due to the equipment fault of direct power purchaser. Combined with the onsite equipment, this paper analyzed and explained the causes of main transformer protection action, raising the corresponding anti-accident measures. Requirements were made to strengthen user equipment supervision and to set down objective protection set value adjustment plan, which provides safe and stable operation for equipment.

Key concepts: Tripping, Transformer, Engineering, Reliability engineering, Electrical equipment, Electrical engineering, Automotive engineering, Forensic engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Analysis of 220 kV Main Transformer Protection Action Caused by Device Failure — Research Paper | ScholarLens