2006•Unpublished venueRequires access

Simultaneous ion Chromatographic Determination of ten Inorganic Anions in Drinking Water

Lai Shao-yang

Open publisher page 0 citations

Abstract

Objective: To establish a mew method for quantitative detection of ten inorganic anion sin drinking water including Fluoride,Chlorite,Bromate,Chloride,Nitrite,Bromide,Chlorate,Nitrate,Phosphate,Sulfate at the same time.Method: IC was carried on the ICS-1000 ion chromatograph with IonpacR AS9 chromatographic column using a mixed solution of 9.0mmol/L Na_2CO_3 as absorbing solution.The sampling was performed at a flow rate of 1.0ml/min.The sample was treated with direct sampling.Result: The threshold of detection:0.004-0.0344mg/L.RSD'S obtained were from1.64% to 3.95%,and the recoveries were from 91.6% to 100.3%.Conclusion: The method was proved to be low disturbing,high sensitive,accurate result and simply,operation.It is adapt to various water samples.It was not effect for acid and alkali coexistence ion and border upon ion.It is adapt to determinate ten inorganic anions.

About this research paper

What this paper is about

Objective: To establish a mew method for quantitative detection of ten inorganic anion sin drinking water including Fluoride,Chlorite,Bromate,Chloride,Nitrite,Bromide,Chlorate,Nitrate,Phosphate,Sulfate at the same time.Method: IC was carried on the ICS-1000 ion chromatograph with IonpacR AS9 chromatographic column using a mixed solution of 9.0mmol/L Na_2CO_3 as absorbing solution.The sampling was performed at a flow rate of 1.0ml/min.The sample was treated with direct sampling.Result: The threshold of detection:0.004-0.0344mg/L.RSD'S obtained were from1.64% to 3.95%,and the recoveries were from 91.6% to 100.3%.Conclusion: The method was proved to be low disturbing,high sensitive,accurate result and simply,operation.It is adapt to various water samples.It was not effect for acid and alkali coexistence ion and border upon ion.It is adapt to determinate ten inorganic anions.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective: To establish a mew method for quantitative detection of ten inorganic anion sin drinking water including Fluoride,Chlorite,Bromate,Chloride,Nitrite,Bromide,Chlorate,Nitrate,Phosphate,Sulfate at the same time.Method: IC was carried on the ICS-1000 ion chromatograph with IonpacR AS9 chromatographic column using a mixed solution of 9.0mmol/L Na_2CO_3 as absorbing solution.The sampling was performed at a flow rate of 1.0ml/min.The sample was treated with direct sampling.Result: The threshold of detection:0.004-0.0344mg/L.RSD'S obtained were from1.64% to 3.95%,and the recoveries were from 91.6% to 100.3%.Conclusion: The method was proved to be low disturbing,high sensitive,accurate result and simply,operation.It is adapt to various water samples.It was not effect for acid and alkali coexistence ion and border upon ion.It is adapt to determinate ten inorganic anions.

Key concepts: Bromate, Chemistry, Bromide, Chlorate, Ion chromatography, Chromatography, Fluoride, Nitrite

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous ion Chromatographic Determination of ten Inorganic Anions in Drinking Water — Research Paper | ScholarLens