2012•Food ScienceRequires access

Simultaneous Determination of Bromate,Chlorite,Chlorate and Common Inorganic Anions in Drinking Water by Ion Chromatography

Hongbin Wang

Open publisher page 0 citations

Abstract

An analytical method for the simultaneous determination of bromate,chlorite,chlorate and common inorganic anions in drinking water was developed using large-volume direct injection and chemically suppressed ion chromatography(IC).An IonPac AS9-HC separation column and an IonPac AG9-HC protection column were used.The mobile phase was 12 mmol/L Na2CO3 at a flow rate of 1.0 mL/min.The injection volume was 100μL.Ten anions could be detected by the method within 18 min with average spike recovery of 93.0%~103.1%(n = 5).The correlation coefficients of calibration curve were 0.9993~0.9999.This method was sensitive,accurate and rapid.It has been applied to determine Kunming tap water and a variety of commercial drinking water with satisfying results.

About this research paper

What this paper is about

An analytical method for the simultaneous determination of bromate,chlorite,chlorate and common inorganic anions in drinking water was developed using large-volume direct injection and chemically suppressed ion chromatography(IC).An IonPac AS9-HC separation column and an IonPac AG9-HC protection column were used.The mobile phase was 12 mmol/L Na2CO3 at a flow rate of 1.0 mL/min.The injection volume was 100μL.Ten anions could be detected by the method within 18 min with average spike recovery of 93.0%~103.1%(n = 5).The correlation coefficients of calibration curve were 0.9993~0.9999.This method was sensitive,accurate and rapid.It has been applied to determine Kunming tap water and a variety of commercial drinking water with satisfying results.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An analytical method for the simultaneous determination of bromate,chlorite,chlorate and common inorganic anions in drinking water was developed using large-volume direct injection and chemically suppressed ion chromatography(IC).An IonPac AS9-HC separation column and an IonPac AG9-HC protection column were used.The mobile phase was 12 mmol/L Na2CO3 at a flow rate of 1.0 mL/min.The injection volume was 100μL.Ten anions could be detected by the method within 18 min with average spike recovery of 93.0%~103.1%(n = 5).The correlation coefficients of calibration curve were 0.9993~0.9999.This method was sensitive,accurate and rapid.It has been applied to determine Kunming tap water and a variety of commercial drinking water with satisfying results.

Key concepts: Chlorate, Bromate, Ion chromatography, Chemistry, Chlorite, Chromatography, Tap water, Volume (thermodynamics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous Determination of Bromate,Chlorite,Chlorate and Common Inorganic Anions in Drinking Water by Ion Chromatography — Research Paper | ScholarLens