2002Applied Mechanics and MaterialsRequires access

A QUANTITATIVE ANALYSIS OF THE SPILLAGE HAZARDS IN THE GAS TANK STORAGE AREAS

Zhang Wu

Open publisher page 0 citations

Abstract

Based on the personal field investigation and literature revision, this paper has done a quantitative analysis of the spillage hazards that are highly likely to happen with the gas production and storage in the gas-container storing areas. The present research focuses its attention on the following key points: First, we have chosen three gas tanks of the storage tank areas (i. e. 10 000 m 3 coal gas tank, 600 m 3 hydrogen tank and 200 m 3 hydrogen middle pressure tank) as the research objects. Second, we have done a careful calculation on the maximum flammable/toxic range in the wind direction by using the spillage model and Gaussian dispersion model for the hazard analysis. Third, sensitivity analysis has been done to identify the influence of the wind speed in the spillage area on the likely hazards. The primary results obtained by the authors include: (1) Among the three storage tanks, the 600 m 3 hydrogen tank has the least severe fire hazard, and the 200 m 3 hydrogen middle pressure tank has the most severe fire hazard. (2) For the 10 000 m 3 coal gas tank, the toxic hazard is more severe than the fire hazard. (3) Wind speed and the spillage area may have strong influence on the spillage hazards. As the spillage area increases, the maximum flammable range down the wind direction increases; however, as the wind speed increases, the maximum flammable range decreases. And, finally, the authors have brought about some effective safety suggestions on the preventive work.

About this research paper

What this paper is about

Based on the personal field investigation and literature revision, this paper has done a quantitative analysis of the spillage hazards that are highly likely to happen with the gas production and storage in the gas-container storing areas. The present research focuses its attention on the following key points: First, we have chosen three gas tanks of the storage tank areas (i. e. 10 000 m 3 coal gas tank, 600 m 3 hydrogen tank and 200 m 3 hydrogen middle pressure tank) as the research objects. Second, we have done a careful calculation on the maximum flammable/toxic range in the wind direction by using the spillage model and Gaussian dispersion model for the hazard analysis. Third, sensitivity analysis has been done to identify the influence of the wind speed in the spillage area on the likely hazards. The primary results obtained by the authors include: (1) Among the three storage tanks, the 600 m 3 hydrogen tank has the least severe fire hazard, and the 200 m 3 hydrogen middle pressure tank has the most severe fire hazard. (2) For the 10 000 m 3 coal gas tank, the toxic hazard is more severe than the fire hazard. (3) Wind speed and the spillage area may have strong influence on the spillage hazards. As the spillage area increases, the maximum flammable range down the wind direction increases; however, as the wind speed increases, the maximum flammable range decreases. And, finally, the authors have brought about some effective safety suggestions on the preventive work.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Based on the personal field investigation and literature revision, this paper has done a quantitative analysis of the spillage hazards that are highly likely to happen with the gas production and storage in the gas-container storing areas. The present research focuses its attention on the following key points: First, we have chosen three gas tanks of the storage tank areas (i. e. 10 000 m 3 coal gas tank, 600 m 3 hydrogen tank and 200 m 3 hydrogen middle pressure tank) as the research objects. Second, we have done a careful calculation on the maximum flammable/toxic range in the wind direction by using the spillage model and Gaussian dispersion model for the hazard analysis. Third, sensitivity analysis has been done to identify the influence of the wind speed in the spillage area on the likely hazards. The primary results obtained by the authors include: (1) Among the three storage tanks, the 600 m 3 hydrogen tank has the least severe fire hazard, and the 200 m 3 hydrogen middle pressure tank has the most severe fire hazard. (2) For the 10 000 m 3 coal gas tank, the toxic hazard is more severe than the fire hazard. (3) Wind speed and the spillage area may have strong influence on the spillage hazards. As the spillage area increases, the maximum flammable range down the wind direction increases; however, as the wind speed increases, the maximum flammable range decreases. And, finally, the authors have brought about some effective safety suggestions on the preventive work.

Key concepts: Spillage, Flammable liquid, Environmental science, Hazard, Waste management, Hazard analysis, Range (aeronautics), Petroleum engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
A QUANTITATIVE ANALYSIS OF THE SPILLAGE HAZARDS IN THE GAS TANK STORAGE AREAS — Research Paper | ScholarLens