Quantitative Analysis of Amino Acids in Eptifibatide Injection by RP-HPLC
Zhang Yi, Sun Jin-hong, YE Ru-han, Lei Peng, WU Di-ke
Abstract
Zhang Yi, Sun Jin-hong, YE Ru-han, Lei Peng, WU Di-ke
Abstract
A reversed-phase high performance liquid chromatographic method was developed for the determination of amino acids in eptifibatide injection using phenyl isothiocyanate as pro-column derivatization reagent.The chromatographic parameter was optimized,and the analysis of amino acids was performed on a Agilent XDB-C18 column(5 μm,150 mm×4.6 mm),using 0.1 mol/L sodium acetate(adjusting the pH to 6.0 with acetic acid) and acetonitrile(90 ∶ 10,A)-acetonitrile(B) as mobile phase by gradient elution at a flow rate of 1.0 mL/min and an injection volume of 5 μL.The detection wavelength was set at 254 nm,and the column temperature was set at 30 ℃.Under the optimal conditions,the amino acids were effectively separated.good linearities were obtained in the range of 1.23-3.68 mmol/L for all amino acids,with correlation coefficients(r) of 0.999 1-0.999 6.The method showed high selectivity,good repeatability,accuracy and stability,and could be applied in the accurate quantification of amino acids in eptifibatide injection.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A reversed-phase high performance liquid chromatographic method was developed for the determination of amino acids in eptifibatide injection using phenyl isothiocyanate as pro-column derivatization reagent.The chromatographic parameter was optimized,and the analysis of amino acids was performed on a Agilent XDB-C18 column(5 μm,150 mm×4.6 mm),using 0.1 mol/L sodium acetate(adjusting the pH to 6.0 with acetic acid) and acetonitrile(90 ∶ 10,A)-acetonitrile(B) as mobile phase by gradient elution at a flow rate of 1.0 mL/min and an injection volume of 5 μL.The detection wavelength was set at 254 nm,and the column temperature was set at 30 ℃.Under the optimal conditions,the amino acids were effectively separated.good linearities were obtained in the range of 1.23-3.68 mmol/L for all amino acids,with correlation coefficients(r) of 0.999 1-0.999 6.The method showed high selectivity,good repeatability,accuracy and stability,and could be applied in the accurate quantification of amino acids in eptifibatide injection.
Key concepts: Chemistry, Chromatography, Derivatization, Reagent, Acetonitrile, Amino acid, High-performance liquid chromatography, Repeatability