2006Unpublished venueRequires access

Simultaneous determination of amino acids in soil by reversed phase high performance liquid chromatography by using 6-aminoquinoly-N-hydroxysuccinimidyl carbamate as a precolumn derivatization reagent

SM Hou, Jie Sun, He Hb, XD Zhang, YuHuang Wang

Open publisher page 1 citations

Abstract

A reversed phase high performance liquid chromatographic method for simultaneous determination of 17 amino acids in soil was established. The amino acid samples were mixed with 2-aminobutyric acid as the internal standard, derivatized with 6-aminoquinolyl-N-hydroxysuceinimidyl carbarnate (AQC), and then separated on a XTerra C(18)column using 1.8 mmol/L formate ammonium (pH = 3. 0) and acetonitrile solution as a mobile phase with gradient elution technique. The photodiode detector at 248 nm was utilized for amino acid quantification. All 17 amino acid derivatives were separated well when an optimized elution condition was applied. Consequently, good reproducibility, high sensitivity and high precision of the method were achieved. When the amino acid concentration was set at the range of 25 - 600 mu mol/L, the linear correlation coefficients of the amino acids were above 0.99 and the detector limit of each amino acids was lower than 0.5 pmol. Total ion current chromatograms of mass spectrum of 17 AQC derivatized amino acids were obtained. The method provids a new way for intensifying the study of amino acids in soil and environment.

About this research paper

What this paper is about

A reversed phase high performance liquid chromatographic method for simultaneous determination of 17 amino acids in soil was established. The amino acid samples were mixed with 2-aminobutyric acid as the internal standard, derivatized with 6-aminoquinolyl-N-hydroxysuceinimidyl carbarnate (AQC), and then separated on a XTerra C(18)column using 1.8 mmol/L formate ammonium (pH = 3. 0) and acetonitrile solution as a mobile phase with gradient elution technique. The photodiode detector at 248 nm was utilized for amino acid quantification. All 17 amino acid derivatives were separated well when an optimized elution condition was applied. Consequently, good reproducibility, high sensitivity and high precision of the method were achieved. When the amino acid concentration was set at the range of 25 - 600 mu mol/L, the linear correlation coefficients of the amino acids were above 0.99 and the detector limit of each amino acids was lower than 0.5 pmol. Total ion current chromatograms of mass spectrum of 17 AQC derivatized amino acids were obtained. The method provids a new way for intensifying the study of amino acids in soil and environment.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A reversed phase high performance liquid chromatographic method for simultaneous determination of 17 amino acids in soil was established. The amino acid samples were mixed with 2-aminobutyric acid as the internal standard, derivatized with 6-aminoquinolyl-N-hydroxysuceinimidyl carbarnate (AQC), and then separated on a XTerra C(18)column using 1.8 mmol/L formate ammonium (pH = 3. 0) and acetonitrile solution as a mobile phase with gradient elution technique. The photodiode detector at 248 nm was utilized for amino acid quantification. All 17 amino acid derivatives were separated well when an optimized elution condition was applied. Consequently, good reproducibility, high sensitivity and high precision of the method were achieved. When the amino acid concentration was set at the range of 25 - 600 mu mol/L, the linear correlation coefficients of the amino acids were above 0.99 and the detector limit of each amino acids was lower than 0.5 pmol. Total ion current chromatograms of mass spectrum of 17 AQC derivatized amino acids were obtained. The method provids a new way for intensifying the study of amino acids in soil and environment.

Key concepts: Chemistry, Chromatography, Amino acid, Ammonium formate, Derivatization, Detection limit, High-performance liquid chromatography, Reagent

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous determination of amino acids in soil by reversed phase high performance liquid chromatography by using 6-aminoquinoly-N-hydroxysuccinimidyl carbamate as a precolumn derivatization reagent — Research Paper | ScholarLens