2005•Analytical LaboratoryRequires access

Effective determination of trace bismuth in medicine in microemulsion medium

Qiurong Zhang

Open publisher page 0 citations

Abstract

The effects of four kinds of micellar and five kinds of microemulsion were studied on the determination of trace bismuth by spectrphotometry. The results showed that the absorption increased when one or two kinds of micellar and microemulsion were used. The microemulsion is the most effective. In a microemulsion medium containing OP, n-C_4H_9OH, C_7H_(14) and water, Bi(Ⅲ) reacts with salicyl fluorone (SAF) to form a stable red complex at pH 1.0. The absorption maximum of Bi(Ⅲ)-SAF complex locates at 516 nm. The apparent molar absorptivity is 1.17×10~5 L/mol/cm. Beer′s law is obeyed in the range of 0~30 μg Bi(Ⅲ) per 25 mL. The method has been applied to the determination of bismuth in bismuth aluminate compound tablets with satisfactory results.

About this research paper

What this paper is about

The effects of four kinds of micellar and five kinds of microemulsion were studied on the determination of trace bismuth by spectrphotometry. The results showed that the absorption increased when one or two kinds of micellar and microemulsion were used. The microemulsion is the most effective. In a microemulsion medium containing OP, n-C_4H_9OH, C_7H_(14) and water, Bi(Ⅲ) reacts with salicyl fluorone (SAF) to form a stable red complex at pH 1.0. The absorption maximum of Bi(Ⅲ)-SAF complex locates at 516 nm. The apparent molar absorptivity is 1.17×10~5 L/mol/cm. Beer′s law is obeyed in the range of 0~30 μg Bi(Ⅲ) per 25 mL. The method has been applied to the determination of bismuth in bismuth aluminate compound tablets with satisfactory results.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The effects of four kinds of micellar and five kinds of microemulsion were studied on the determination of trace bismuth by spectrphotometry. The results showed that the absorption increased when one or two kinds of micellar and microemulsion were used. The microemulsion is the most effective. In a microemulsion medium containing OP, n-C_4H_9OH, C_7H_(14) and water, Bi(Ⅲ) reacts with salicyl fluorone (SAF) to form a stable red complex at pH 1.0. The absorption maximum of Bi(Ⅲ)-SAF complex locates at 516 nm. The apparent molar absorptivity is 1.17×10~5 L/mol/cm. Beer′s law is obeyed in the range of 0~30 μg Bi(Ⅲ) per 25 mL. The method has been applied to the determination of bismuth in bismuth aluminate compound tablets with satisfactory results.

Key concepts: Microemulsion, Molar absorptivity, Chemistry, Bismuth, Absorption (acoustics), Trace Amounts, Nuclear chemistry, Inorganic chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Effective determination of trace bismuth in medicine in microemulsion medium — Research Paper | ScholarLens