2009Physical Testing and Chemical AnalysisRequires access

FAAS Determination of Lead in Waste Gas

Lin Lin

Open publisher page 0 citations

Abstract

The blank filtering cartridge was rinsed with dil. HNO_3 to eliminate lead ion, then used to absorb waste gas. The above filtering cartridge was digested by three different methods, including microwave assisted digestion, acid digestion method and Soxhlet extraction, and the solution obtained was determined by FAAS. Microwave digestion was chosen by comparing the values recovery of the 3 digestion methods. Linear relationship between the values of absorption and mass concentration of lead was kept in the range of 0. 5-5. 0 mg·L~(-1), with the values of recovery found by standard addition method in the range of 93. 0%-96. 2%.

About this research paper

What this paper is about

The blank filtering cartridge was rinsed with dil. HNO_3 to eliminate lead ion, then used to absorb waste gas. The above filtering cartridge was digested by three different methods, including microwave assisted digestion, acid digestion method and Soxhlet extraction, and the solution obtained was determined by FAAS. Microwave digestion was chosen by comparing the values recovery of the 3 digestion methods. Linear relationship between the values of absorption and mass concentration of lead was kept in the range of 0. 5-5. 0 mg·L~(-1), with the values of recovery found by standard addition method in the range of 93. 0%-96. 2%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The blank filtering cartridge was rinsed with dil. HNO_3 to eliminate lead ion, then used to absorb waste gas. The above filtering cartridge was digested by three different methods, including microwave assisted digestion, acid digestion method and Soxhlet extraction, and the solution obtained was determined by FAAS. Microwave digestion was chosen by comparing the values recovery of the 3 digestion methods. Linear relationship between the values of absorption and mass concentration of lead was kept in the range of 0. 5-5. 0 mg·L~(-1), with the values of recovery found by standard addition method in the range of 93. 0%-96. 2%.

Key concepts: Cartridge, Digestion (alchemy), Microwave digestion, Chemistry, Extraction (chemistry), Chromatography, Microwave oven, Standard addition

Related papers

Back to paper searchBrowse research topicsOriginal source
FAAS Determination of Lead in Waste Gas — Research Paper | ScholarLens