2009Food ScienceRequires access

Atomic Fluorescence Spectrometric Determination of Trace Selenium in Chinese Date

Hui Rui-hua

Open publisher page 0 citations

Abstract

An atomic fluorescence spectrometric method was developed to determine trace selenium in Chinese date by taking 10% HCl solution as the current-carrying solution,selecting 2.0% potassium borohydride solution to enhance fluorescence intensity,and eliminating the disturbance of Pb2+,Cu2+ and Ag+ by enrichment with mercapto cotton and masking with thiourea-ascorbic acid.Results showed that the linear range and detection limit were 1.0-32.0 ng/ml and 0.57 ng/ml,respectively;the recovery varied from 99.0% to 106.3% and the RSD was lower than 1.71%.

About this research paper

What this paper is about

An atomic fluorescence spectrometric method was developed to determine trace selenium in Chinese date by taking 10% HCl solution as the current-carrying solution,selecting 2.0% potassium borohydride solution to enhance fluorescence intensity,and eliminating the disturbance of Pb2+,Cu2+ and Ag+ by enrichment with mercapto cotton and masking with thiourea-ascorbic acid.Results showed that the linear range and detection limit were 1.0-32.0 ng/ml and 0.57 ng/ml,respectively;the recovery varied from 99.0% to 106.3% and the RSD was lower than 1.71%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An atomic fluorescence spectrometric method was developed to determine trace selenium in Chinese date by taking 10% HCl solution as the current-carrying solution,selecting 2.0% potassium borohydride solution to enhance fluorescence intensity,and eliminating the disturbance of Pb2+,Cu2+ and Ag+ by enrichment with mercapto cotton and masking with thiourea-ascorbic acid.Results showed that the linear range and detection limit were 1.0-32.0 ng/ml and 0.57 ng/ml,respectively;the recovery varied from 99.0% to 106.3% and the RSD was lower than 1.71%.

Key concepts: Selenium, Chemistry, Detection limit, Thiourea, Ascorbic acid, Masking agent, Fluorescence, Linear range

Related papers

Back to paper searchBrowse research topicsOriginal source
Atomic Fluorescence Spectrometric Determination of Trace Selenium in Chinese Date — Research Paper | ScholarLens