2008•Metallurgical AnalysisRequires access

Determination of multi-elements in aluminum alloys by using microwave digestion inductively coupled plasma mass spectrometry

Yan-zhi Shi

Open publisher page 0 citations

Abstract

A method was studied for the determination of Be,Mg,V,Cr,Mn,Fe,Ni,Cu,Zn,Ga,Cd,Sb,Sn and Pb in aluminum alloy by microwave digestion sample and inductively coupled plasma mass spectrometry(ICP-MS).To overcome mass spectroscopic and non-spectroscopic interference effect in high TDS(total dissolved solid) solution,the plasma conditions have been developed systematically and internal standard calibration was applied without matrix matching.The correlation coefficient of calibration curve was no less than 0.999.The detection limits of the method were 0.01-0.45 μg/g(3σ,n=11).Two CRMs have been measured and good agreement was obtained between the found and certified values.The relative standard deviations(RSD) for all the elements were less than 6.7%.

About this research paper

What this paper is about

A method was studied for the determination of Be,Mg,V,Cr,Mn,Fe,Ni,Cu,Zn,Ga,Cd,Sb,Sn and Pb in aluminum alloy by microwave digestion sample and inductively coupled plasma mass spectrometry(ICP-MS).To overcome mass spectroscopic and non-spectroscopic interference effect in high TDS(total dissolved solid) solution,the plasma conditions have been developed systematically and internal standard calibration was applied without matrix matching.The correlation coefficient of calibration curve was no less than 0.999.The detection limits of the method were 0.01-0.45 μg/g(3σ,n=11).Two CRMs have been measured and good agreement was obtained between the found and certified values.The relative standard deviations(RSD) for all the elements were less than 6.7%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method was studied for the determination of Be,Mg,V,Cr,Mn,Fe,Ni,Cu,Zn,Ga,Cd,Sb,Sn and Pb in aluminum alloy by microwave digestion sample and inductively coupled plasma mass spectrometry(ICP-MS).To overcome mass spectroscopic and non-spectroscopic interference effect in high TDS(total dissolved solid) solution,the plasma conditions have been developed systematically and internal standard calibration was applied without matrix matching.The correlation coefficient of calibration curve was no less than 0.999.The detection limits of the method were 0.01-0.45 μg/g(3σ,n=11).Two CRMs have been measured and good agreement was obtained between the found and certified values.The relative standard deviations(RSD) for all the elements were less than 6.7%.

Key concepts: Inductively coupled plasma mass spectrometry, Analytical Chemistry (journal), Microwave digestion, Chemistry, Certified reference materials, Calibration curve, Mass spectrometry, Inductively coupled plasma

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of multi-elements in aluminum alloys by using microwave digestion inductively coupled plasma mass spectrometry — Research Paper | ScholarLens