2000•Chinese Journal of TraumatologyRequires access

Measurement of periprosthetic bone mineral density after hip arthroplasty

Zhang Quan

Open publisher page 0 citations

Abstract

Objective To measure the periprosthetic bone mineral density (BMD) after uncemented hip arthroplasty by applying the upgraded Dual energy X ray absorptiometry (DEXA) method. Methods Forty six patients who had the hip replaced in our hospital in recent 5 years were studied. All the patients had X ray and the BMD of both femurs were measured with the upgraded DEXA method. Results The BMD decreased rapidly in the first year after operation, but patients with higher BMD lost less bone. The BMD in the medial part of the stem and in the trochanter decreased most, the bone at the lateral part of the stem lost less, and at the tip of the stem the lest. The collar of the stem could reduce bone loss at the calcar region. The gender, age and weight, all these factors were not related with the bone loss. Conclusions The upgraded DEXA is a precise and reliable method in clinical follow up after hip arthroplasty.

About this research paper

What this paper is about

Objective To measure the periprosthetic bone mineral density (BMD) after uncemented hip arthroplasty by applying the upgraded Dual energy X ray absorptiometry (DEXA) method. Methods Forty six patients who had the hip replaced in our hospital in recent 5 years were studied. All the patients had X ray and the BMD of both femurs were measured with the upgraded DEXA method. Results The BMD decreased rapidly in the first year after operation, but patients with higher BMD lost less bone. The BMD in the medial part of the stem and in the trochanter decreased most, the bone at the lateral part of the stem lost less, and at the tip of the stem the lest. The collar of the stem could reduce bone loss at the calcar region. The gender, age and weight, all these factors were not related with the bone loss. Conclusions The upgraded DEXA is a precise and reliable method in clinical follow up after hip arthroplasty.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To measure the periprosthetic bone mineral density (BMD) after uncemented hip arthroplasty by applying the upgraded Dual energy X ray absorptiometry (DEXA) method. Methods Forty six patients who had the hip replaced in our hospital in recent 5 years were studied. All the patients had X ray and the BMD of both femurs were measured with the upgraded DEXA method. Results The BMD decreased rapidly in the first year after operation, but patients with higher BMD lost less bone. The BMD in the medial part of the stem and in the trochanter decreased most, the bone at the lateral part of the stem lost less, and at the tip of the stem the lest. The collar of the stem could reduce bone loss at the calcar region. The gender, age and weight, all these factors were not related with the bone loss. Conclusions The upgraded DEXA is a precise and reliable method in clinical follow up after hip arthroplasty.

Key concepts: Calcar, Periprosthetic, Medicine, Bone mineral, Greater trochanter, Trochanter, Femoral neck, Hip arthroplasty

Related papers

Back to paper searchBrowse research topicsOriginal source
Measurement of periprosthetic bone mineral density after hip arthroplasty — Research Paper | ScholarLens