2001•Journal of Bone and Mineral ResearchRequires access

Monitoring of Periprosthetic BMD After Uncemented Total Hip Arthroplasty with Dual-Energy X-Ray Absorptiometry—a 3-Year Follow-Up Study

Petri K. Venesmaa, Heikki Kröger, Hannu J. A. Miettinen, Jukka Sakari Jurvelin, Olavi T. Suomalainen, Esko M. Alhava

Open publisher page 176 citations

Abstract

Insertion of a metallic implant into the femur changes bone loading conditions and results in remodeling of femoral bone. To quantify changes in bone mass after uncemented total hip arthroplasty (THA), we monitored femoral bone with dual-energy X-ray absorptiometry (DXA). The periprosthetic bone mineral density (BMD) was measured with Lunar DPX densitometry in seven Gruen zones and the total periprosthetic area at scheduled time intervals in 22 patients during a 3-year follow-up. BMD decreased significantly almost in all Gruen zones during the first 3 months, ranging from 3.4% to 14.4% (p < 0.05 top < 0.001). At the end of the first year, the most remarkable decrease in BMD was found in the calcar (zone 7; -22.9%). During the second postoperative year, a slight restoration of periprosthetic bone mass was recorded. During the third year, no significant changes in BMD were found. The preoperative BMD was the only factor that was significantly related to the periprosthetic bone loss. Clearly, the early periprosthetic bone loss noticed during the 3 months after THA is caused by mainly limited weight bearing to the operated hip and stress shielding. We suggest that the restoration of bone mass is a sign of successful osteointegration between bone and metallic implant. DXA is a suitable tool to follow the bone response to prosthetization and will increase our knowledge on the behavior of bone after THA.

About this research paper

What this paper is about

Insertion of a metallic implant into the femur changes bone loading conditions and results in remodeling of femoral bone. To quantify changes in bone mass after uncemented total hip arthroplasty (THA), we monitored femoral bone with dual-energy X-ray absorptiometry (DXA). The periprosthetic bone mineral density (BMD) was measured with Lunar DPX densitometry in seven Gruen zones and the total periprosthetic area at scheduled time intervals in 22 patients during a 3-year follow-up. BMD decreased significantly almost in all Gruen zones during the first 3 months, ranging from 3.4% to 14.4% (p < 0.05 top < 0.001). At the end of the first year, the most remarkable decrease in BMD was found in the calcar (zone 7; -22.9%). During the second postoperative year, a slight restoration of periprosthetic bone mass was recorded. During the third year, no significant changes in BMD were found. The preoperative BMD was the only factor that was significantly related to the periprosthetic bone loss. Clearly, the early periprosthetic bone loss noticed during the 3 months after THA is caused by mainly limited weight bearing to the operated hip and stress shielding. We suggest that the restoration of bone mass is a sign of successful osteointegration between bone and metallic implant. DXA is a suitable tool to follow the bone response to prosthetization and will increase our knowledge on the behavior of bone after THA.

Why it matters

OpenAlex reports 176 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Insertion of a metallic implant into the femur changes bone loading conditions and results in remodeling of femoral bone. To quantify changes in bone mass after uncemented total hip arthroplasty (THA), we monitored femoral bone with dual-energy X-ray absorptiometry (DXA). The periprosthetic bone mineral density (BMD) was measured with Lunar DPX densitometry in seven Gruen zones and the total periprosthetic area at scheduled time intervals in 22 patients during a 3-year follow-up. BMD decreased significantly almost in all Gruen zones during the first 3 months, ranging from 3.4% to 14.4% (p < 0.05 top < 0.001). At the end of the first year, the most remarkable decrease in BMD was found in the calcar (zone 7; -22.9%). During the second postoperative year, a slight restoration of periprosthetic bone mass was recorded. During the third year, no significant changes in BMD were found. The preoperative BMD was the only factor that was significantly related to the periprosthetic bone loss. Clearly, the early periprosthetic bone loss noticed during the 3 months after THA is caused by mainly limited weight bearing to the operated hip and stress shielding. We suggest that the restoration of bone mass is a sign of successful osteointegration between bone and metallic implant. DXA is a suitable tool to follow the bone response to prosthetization and will increase our knowledge on the behavior of bone after THA.

Key concepts: Periprosthetic, Stress shielding, Medicine, Calcar, Bone mineral, Dual-energy X-ray absorptiometry, Femur, Densitometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Monitoring of Periprosthetic BMD After Uncemented Total Hip Arthroplasty with Dual-Energy X-Ray Absorptiometry—a 3-Year Follow-Up Study — Research Paper | ScholarLens