2013Electrical Measurement & InstrumentationRequires access

IEC61850 Revamping of Microcomputer-Based Transmission Line Protection

Wen Yang-don

Open publisher page 1 citations

Abstract

It is necessary to update the traditional microprocessor-based protection device to meet IEC61850 in the transformation of digital substation. Taking microcomputer-based transmission line protection as an example, this paper adds communication module to the original hardware to realize its external communication through Ethernet to meet the IEC61850 communication standard. Decomposition of functions and identification of logical nodes and logical devices are performed for the protection device, and data model of longitudinal differential protection is build. Finally the IEC61850 information model and service are completed. The modeling method used in this paper has better application value for other protection equipment and good reference significance to the study and practice of IEC61850 standard.

About this research paper

What this paper is about

It is necessary to update the traditional microprocessor-based protection device to meet IEC61850 in the transformation of digital substation. Taking microcomputer-based transmission line protection as an example, this paper adds communication module to the original hardware to realize its external communication through Ethernet to meet the IEC61850 communication standard. Decomposition of functions and identification of logical nodes and logical devices are performed for the protection device, and data model of longitudinal differential protection is build. Finally the IEC61850 information model and service are completed. The modeling method used in this paper has better application value for other protection equipment and good reference significance to the study and practice of IEC61850 standard.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

It is necessary to update the traditional microprocessor-based protection device to meet IEC61850 in the transformation of digital substation. Taking microcomputer-based transmission line protection as an example, this paper adds communication module to the original hardware to realize its external communication through Ethernet to meet the IEC61850 communication standard. Decomposition of functions and identification of logical nodes and logical devices are performed for the protection device, and data model of longitudinal differential protection is build. Finally the IEC61850 information model and service are completed. The modeling method used in this paper has better application value for other protection equipment and good reference significance to the study and practice of IEC61850 standard.

Key concepts: IEC 61850, Ethernet, Microcomputer, Microprocessor, Computer science, Differential protection, Transmission (telecommunications), Line (geometry)

Related papers

Back to paper searchBrowse research topicsOriginal source
IEC61850 Revamping of Microcomputer-Based Transmission Line Protection — Research Paper | ScholarLens