2011•Unpublished venueRequires access

Design and performance evaluation for a protection system utilising IEC 61850-9-2 process bus

Peter A. Crossley, Li Yang, Wen An, Ray Chatfield, Miles Redfern, Xin Sun

Open publisher page 8 citations

Abstract

The use of process-bus technology, designed in accordance with the IEC 61850 standard, introduces new opportunities for protection and control. However, before the technology can be deployed, adequate tests are required to prove use of the process bus does not have a detrimental impact on the operating performance of future protection, as expressed in terms of dependability, security and operating speed. The paper will describe an overview of the concepts and benefits of the process bus, and how it affects the design of prototype protection scheme suitable for the mesh-corner of a transmission substation. The operating characteristics of conventional hardwired relays and IEC 61850-9-2LE relays applied within a feeder protection scheme, were compared and assessed against conventional type-test results. The scheme includes Ethernet Switches from different manufacturers, configured to allow the assessment of different process-bus architectures. The effect of interchangeability and time offsets were investigated both experimentally and using the OPNET simulator. The scheme includes Merging Units (MU), tested to assess the magnitude of their time offset and how they drift with time and temperature. Causes of incorrect operation were recognized and recommendations presented to avoid the degradation of system performance. Given an appropriate configuration, the performance of a process bus based protection scheme is comparable to a conventional hardwired scheme. The presented results provides a fundamental reference for all the participating parties to create a roadmap for the efficient application and deployment of protection and control systems based on IEC 61850 process bus and digital Ethernet communications.

About this research paper

What this paper is about

The use of process-bus technology, designed in accordance with the IEC 61850 standard, introduces new opportunities for protection and control. However, before the technology can be deployed, adequate tests are required to prove use of the process bus does not have a detrimental impact on the operating performance of future protection, as expressed in terms of dependability, security and operating speed. The paper will describe an overview of the concepts and benefits of the process bus, and how it affects the design of prototype protection scheme suitable for the mesh-corner of a transmission substation. The operating characteristics of conventional hardwired relays and IEC 61850-9-2LE relays applied within a feeder protection scheme, were compared and assessed against conventional type-test results. The scheme includes Ethernet Switches from different manufacturers, configured to allow the assessment of different process-bus architectures. The effect of interchangeability and time offsets were investigated both experimentally and using the OPNET simulator. The scheme includes Merging Units (MU), tested to assess the magnitude of their time offset and how they drift with time and temperature. Causes of incorrect operation were recognized and recommendations presented to avoid the degradation of system performance. Given an appropriate configuration, the performance of a process bus based protection scheme is comparable to a conventional hardwired scheme. The presented results provides a fundamental reference for all the participating parties to create a roadmap for the efficient application and deployment of protection and control systems based on IEC 61850 process bus and digital Ethernet communications.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The use of process-bus technology, designed in accordance with the IEC 61850 standard, introduces new opportunities for protection and control. However, before the technology can be deployed, adequate tests are required to prove use of the process bus does not have a detrimental impact on the operating performance of future protection, as expressed in terms of dependability, security and operating speed. The paper will describe an overview of the concepts and benefits of the process bus, and how it affects the design of prototype protection scheme suitable for the mesh-corner of a transmission substation. The operating characteristics of conventional hardwired relays and IEC 61850-9-2LE relays applied within a feeder protection scheme, were compared and assessed against conventional type-test results. The scheme includes Ethernet Switches from different manufacturers, configured to allow the assessment of different process-bus architectures. The effect of interchangeability and time offsets were investigated both experimentally and using the OPNET simulator. The scheme includes Merging Units (MU), tested to assess the magnitude of their time offset and how they drift with time and temperature. Causes of incorrect operation were recognized and recommendations presented to avoid the degradation of system performance. Given an appropriate configuration, the performance of a process bus based protection scheme is comparable to a conventional hardwired scheme. The presented results provides a fundamental reference for all the participating parties to create a roadmap for the efficient application and deployment of protection and control systems based on IEC 61850 process bus and digital Ethernet communications.

Key concepts: IEC 61850, Ethernet, Embedded system, Process (computing), Reliability engineering, Scheme (mathematics), Industrial Ethernet, Computer science

Related papers

Back to paper searchBrowse research topicsOriginal source
Design and performance evaluation for a protection system utilising IEC 61850-9-2 process bus — Research Paper | ScholarLens