2012•Zhongguo yaofangRequires access

Content Determination of Eucommiol in Eucommia ulmoides by RP-HPLC

Nanyin Han

Open publisher page 0 citations

Abstract

OBJECTIVE: To develop the method for the content determination of eucommiol in Eucommia ulmoides. METHODS: RP-HPLC method was adopted. The sample was separated on Chromasail C18(250 mm×4.6 mm,5 μm) column with methanol-water (8 ∶ 92) as the mobile phase at the flow rate of 1 mL·min-1. The column temperature was 25 ℃and the detection wavelength was set at 210 nm. RESULTS: The linear range of eucommiol was 0.467 6~5.845 0 μg(r=0.999 9) with an average recovery of 99.04%(RSD=2.16%,n=9). CONCLUSION: The method is simple, stable, controllable and repeatable, and it could be used for the content determination of encommiol in Eucommia ulmoide.

About this research paper

What this paper is about

OBJECTIVE: To develop the method for the content determination of eucommiol in Eucommia ulmoides. METHODS: RP-HPLC method was adopted. The sample was separated on Chromasail C18(250 mm×4.6 mm,5 μm) column with methanol-water (8 ∶ 92) as the mobile phase at the flow rate of 1 mL·min-1. The column temperature was 25 ℃and the detection wavelength was set at 210 nm. RESULTS: The linear range of eucommiol was 0.467 6~5.845 0 μg(r=0.999 9) with an average recovery of 99.04%(RSD=2.16%,n=9). CONCLUSION: The method is simple, stable, controllable and repeatable, and it could be used for the content determination of encommiol in Eucommia ulmoide.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To develop the method for the content determination of eucommiol in Eucommia ulmoides. METHODS: RP-HPLC method was adopted. The sample was separated on Chromasail C18(250 mm×4.6 mm,5 μm) column with methanol-water (8 ∶ 92) as the mobile phase at the flow rate of 1 mL·min-1. The column temperature was 25 ℃and the detection wavelength was set at 210 nm. RESULTS: The linear range of eucommiol was 0.467 6~5.845 0 μg(r=0.999 9) with an average recovery of 99.04%(RSD=2.16%,n=9). CONCLUSION: The method is simple, stable, controllable and repeatable, and it could be used for the content determination of encommiol in Eucommia ulmoide.

Key concepts: Eucommia ulmoides, Chromatography, High-performance liquid chromatography, Content determination, Chemistry, Linear range, Linear relationship, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Content Determination of Eucommiol in Eucommia ulmoides by RP-HPLC — Research Paper | ScholarLens