Near Infrared Determination of Sugar Content in Kiwifruits Based on siPLS
Tang Mingjie
Abstract
Tang Mingjie
Abstract
In order to quest an approach to measure sugar content of kiwifruit rapidly and nondestructively,wavelet denoising was used to preprocess the near infrared(NIR) spectra(1000 to 2500 nm) of kiwifruit.Partial least square(PLS),interval partial least square(iPLS) and synergy interval partial least square(siPLS) methods were used to establish the calibration models of sugar content.Experimental results showed that the optimal siPLS model is obtained with 16 intervals and the optimal combinations of intervals are number 9,11 and 13.The model is achieved with correlation coefficient 0.9414 and root mean square error of cross validation(RMSECV) 0.3788 in calibration set and correlation coefficient 0.9295 and RMSEP 0.3904 in prediction set,and its factor number is 7.This study demonstrated that NIR spectroscopy with siPLS model could not only diminish run time and select the optimal intervals,but also improve precision.
OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
In order to quest an approach to measure sugar content of kiwifruit rapidly and nondestructively,wavelet denoising was used to preprocess the near infrared(NIR) spectra(1000 to 2500 nm) of kiwifruit.Partial least square(PLS),interval partial least square(iPLS) and synergy interval partial least square(siPLS) methods were used to establish the calibration models of sugar content.Experimental results showed that the optimal siPLS model is obtained with 16 intervals and the optimal combinations of intervals are number 9,11 and 13.The model is achieved with correlation coefficient 0.9414 and root mean square error of cross validation(RMSECV) 0.3788 in calibration set and correlation coefficient 0.9295 and RMSEP 0.3904 in prediction set,and its factor number is 7.This study demonstrated that NIR spectroscopy with siPLS model could not only diminish run time and select the optimal intervals,but also improve precision.
Key concepts: Mean squared error, Correlation coefficient, Calibration, Content (measure theory), Analytical Chemistry (journal), Sugar, Coefficient of determination, Mathematics