Simultaneous Determination of Contents of Triamcinolone Acetonide Acetate and Miconazole Nitrate in Triamcinolone Acetonide Acetate and Miconazole Nitrate and Neomycin Sulfate Cream by RP-HPLC
Yang Jingjing
Abstract
Yang Jingjing
Abstract
Objective To establish an RP-HPLC method for the simultaneous determination of contents of triamcinolone acetonide acetate and miconazole nitrate in triamcinolone acetonide acetate and miconazole nitrate and neomycin sulfate cream.Methods RP-HPLC was conducted using a Diamonsil C18 column(200 mm×4.6 mm,5 μm),with a mobile phase of 0.5% ammonium acetate solution--acetonitrile--methanol(15:42.5:42.5)and flow rate of 1.0 mL·min-1.Samples was detected at 272 nm,with dibutyl phthalate as internal standard.Results The linear range was 64.08-149.52 μg·mL-1(r=0.999 9)and the average recovery rate was 99.6%,RSD=0.43%(n=6)for triamcinolone acetonide acetate.The linear range was 600.6-1 401.4 μg·mL-1(r=0.999 9),the average recovery rate was 100.0%,RSD=0.49%(n=6)for miconazole nitrate.Conclusion The method was accurate,simple and effective.It might effectively be applied to control the quality of agent.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To establish an RP-HPLC method for the simultaneous determination of contents of triamcinolone acetonide acetate and miconazole nitrate in triamcinolone acetonide acetate and miconazole nitrate and neomycin sulfate cream.Methods RP-HPLC was conducted using a Diamonsil C18 column(200 mm×4.6 mm,5 μm),with a mobile phase of 0.5% ammonium acetate solution--acetonitrile--methanol(15:42.5:42.5)and flow rate of 1.0 mL·min-1.Samples was detected at 272 nm,with dibutyl phthalate as internal standard.Results The linear range was 64.08-149.52 μg·mL-1(r=0.999 9)and the average recovery rate was 99.6%,RSD=0.43%(n=6)for triamcinolone acetonide acetate.The linear range was 600.6-1 401.4 μg·mL-1(r=0.999 9),the average recovery rate was 100.0%,RSD=0.49%(n=6)for miconazole nitrate.Conclusion The method was accurate,simple and effective.It might effectively be applied to control the quality of agent.
Key concepts: Triamcinolone acetonide, Miconazole Nitrate, Chemistry, High-performance liquid chromatography, Chromatography, Miconazole, Ammonium acetate, Medicine