Simulation Research and Fault Line Selection of Single-phase Grounding Fault in 10 kV Distribution Network

Feng Zhao

Open publisher page 1 citations

Abstract

The fault line selection of single-phase grounding fault in 10 kV distribution network has not been well solved,due to which fault condition intricately and fault current too small.On the basis of analysis to fault transient characteristics of system when occur single-phase-to-earth fault,the single phase grounding fault of power system with neutral grounding via arc suppression coil is simulated.A method of single- phase grounding line selection in small current grounding system was put forward,based on comparison difference of transient zero sequence current absolute value of each line in a power frequency cycle.At the same time,principle and procedure of fault line selection of the method were introduced.The MATLAB Simulations indicate that the method can find out the faulty line correctly.It has a high sensitivity and cannot be affected by fault resistances and fault current angles and other factors.

About this research paper

What this paper is about

The fault line selection of single-phase grounding fault in 10 kV distribution network has not been well solved,due to which fault condition intricately and fault current too small.On the basis of analysis to fault transient characteristics of system when occur single-phase-to-earth fault,the single phase grounding fault of power system with neutral grounding via arc suppression coil is simulated.A method of single- phase grounding line selection in small current grounding system was put forward,based on comparison difference of transient zero sequence current absolute value of each line in a power frequency cycle.At the same time,principle and procedure of fault line selection of the method were introduced.The MATLAB Simulations indicate that the method can find out the faulty line correctly.It has a high sensitivity and cannot be affected by fault resistances and fault current angles and other factors.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The fault line selection of single-phase grounding fault in 10 kV distribution network has not been well solved,due to which fault condition intricately and fault current too small.On the basis of analysis to fault transient characteristics of system when occur single-phase-to-earth fault,the single phase grounding fault of power system with neutral grounding via arc suppression coil is simulated.A method of single- phase grounding line selection in small current grounding system was put forward,based on comparison difference of transient zero sequence current absolute value of each line in a power frequency cycle.At the same time,principle and procedure of fault line selection of the method were introduced.The MATLAB Simulations indicate that the method can find out the faulty line correctly.It has a high sensitivity and cannot be affected by fault resistances and fault current angles and other factors.

Key concepts: Ground, Fault (geology), Transient (computer programming), Earthing system, Fault indicator, Symmetrical components, Engineering, Line (geometry)