A novel location method for single-phase grounding fault in small current grounding distribution network based on difference of phase current fault component between fault and non-fault phases

LU Su-yan, Xiaohua Ding, Biaolong Su

Open publisher page 8 citations

Abstract

Single-phase grounding fault is the most frequent fault in distribution network small current grounding systems. But the misjudgment ratios of existing location methods are always high, which influences the power distribution stability. This is due to a series of problems such as insignificant characteristics of steady-state electrical quantities and short duration of transient zero-sequence fault characteristics. After studying a typical fault characteristic called phase current fault component, the experiments show that when single-phase grounding fault occurs, the phase current fault component waveforms of fault and non-fault phases are significantly different in fault upstream sections. On the other hand, in downstream and non-fault sections, the waveforms are basically the same. With this conclusion, a new fault section location scheme for single-phase grounding fault in distribution networks is designed based on difference of phase current fault component between fault and non-fault phases. And the reliability and sensitivity of this method are proved under multiple conditions in the PSCAD simulation environment.

About this research paper

What this paper is about

Single-phase grounding fault is the most frequent fault in distribution network small current grounding systems. But the misjudgment ratios of existing location methods are always high, which influences the power distribution stability. This is due to a series of problems such as insignificant characteristics of steady-state electrical quantities and short duration of transient zero-sequence fault characteristics. After studying a typical fault characteristic called phase current fault component, the experiments show that when single-phase grounding fault occurs, the phase current fault component waveforms of fault and non-fault phases are significantly different in fault upstream sections. On the other hand, in downstream and non-fault sections, the waveforms are basically the same. With this conclusion, a new fault section location scheme for single-phase grounding fault in distribution networks is designed based on difference of phase current fault component between fault and non-fault phases. And the reliability and sensitivity of this method are proved under multiple conditions in the PSCAD simulation environment.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Single-phase grounding fault is the most frequent fault in distribution network small current grounding systems. But the misjudgment ratios of existing location methods are always high, which influences the power distribution stability. This is due to a series of problems such as insignificant characteristics of steady-state electrical quantities and short duration of transient zero-sequence fault characteristics. After studying a typical fault characteristic called phase current fault component, the experiments show that when single-phase grounding fault occurs, the phase current fault component waveforms of fault and non-fault phases are significantly different in fault upstream sections. On the other hand, in downstream and non-fault sections, the waveforms are basically the same. With this conclusion, a new fault section location scheme for single-phase grounding fault in distribution networks is designed based on difference of phase current fault component between fault and non-fault phases. And the reliability and sensitivity of this method are proved under multiple conditions in the PSCAD simulation environment.

Key concepts: Ground, Fault (geology), Fault indicator, Stuck-at fault, Symmetrical components, Waveform, Fault coverage, Fault model