2014Detergent & CosmeticsRequires access

Trace analysis of cadmium in cosmetics by cold-vapor generation- atomic absorption spectrometry with microwave digestion

HU Jia-we

Open publisher page 0 citations

Abstract

A method for the determination of trace amounts of cadmium in cosmetics by cold-vapor generation-atomic absorption spectrometry with microwave digestion was developed. The samples were digested by microwave and the temperature and time of microwave digestion were optimized. Such factors affecting the determination as flow rate of carrier gas, acidity, amount of added sensitizer and interference from coexisted ions were investigated. Under the optimal test conditions, the liner concentration range of the method was between 0~40 μg/L; the limit of detection of cadmium was 0.050 μg/L, the recovery range of standard addition was 95.4%~103.3% and relative standard deviation(RSD) below4.6 %.

About this research paper

What this paper is about

A method for the determination of trace amounts of cadmium in cosmetics by cold-vapor generation-atomic absorption spectrometry with microwave digestion was developed. The samples were digested by microwave and the temperature and time of microwave digestion were optimized. Such factors affecting the determination as flow rate of carrier gas, acidity, amount of added sensitizer and interference from coexisted ions were investigated. Under the optimal test conditions, the liner concentration range of the method was between 0~40 μg/L; the limit of detection of cadmium was 0.050 μg/L, the recovery range of standard addition was 95.4%~103.3% and relative standard deviation(RSD) below4.6 %.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method for the determination of trace amounts of cadmium in cosmetics by cold-vapor generation-atomic absorption spectrometry with microwave digestion was developed. The samples were digested by microwave and the temperature and time of microwave digestion were optimized. Such factors affecting the determination as flow rate of carrier gas, acidity, amount of added sensitizer and interference from coexisted ions were investigated. Under the optimal test conditions, the liner concentration range of the method was between 0~40 μg/L; the limit of detection of cadmium was 0.050 μg/L, the recovery range of standard addition was 95.4%~103.3% and relative standard deviation(RSD) below4.6 %.

Key concepts: Microwave digestion, Cadmium, Detection limit, Microwave, Chemistry, Atomic absorption spectroscopy, Analytical Chemistry (journal), Mass spectrometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Trace analysis of cadmium in cosmetics by cold-vapor generation- atomic absorption spectrometry with microwave digestion — Research Paper | ScholarLens