Objective:To provide objective anatomy data for the diagnosis of brain disease in nomal neonates by observig brain volume by CT.Methods:To measure the brain volume of 42 neonates with normal head CT scanning.Nine items of brain volume were abtained with volume analysis software by spreading the selected area with the gray-scale method.Results:The mean values of nine items of neonates brain were obtained,the whole brain volume was(419.15 ±5.33)cm3,the volume of the left cerebral hemisphere was(187.62 ±2.91)cm3,the right cerebral hemisphere volume was(187.61 ±3.38)cm3,the volume of the left cerebellar hemisphere was(17.15 ±1.05)cm3,the right cerebellar hemisphere volume was(16.99 ±0.85)cm3,the left lateral ventricle volume was(3.76 ±0.07)cm3,the right lateral ventricle volume was(3.75 ±0.08)cm3,the third ventricle volume was(0.22 ±0.01)cm3,the fourth ventricle volume was(0.24 ±0.01)cm3,and there was no statistically significant differences in comparison between the volume of the left and right cerebral hemisphere,the left and right cerebellar hemisphere,the left and right lateral ventricle(P0.05).Conclusion:MSCT is accurate and reliable in vivo measurement of the normal neonatal brain volume,so it can recognize the CT anatomy of normal neonatal brain from imaging perspective.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective:To provide objective anatomy data for the diagnosis of brain disease in nomal neonates by observig brain volume by CT.Methods:To measure the brain volume of 42 neonates with normal head CT scanning.Nine items of brain volume were abtained with volume analysis software by spreading the selected area with the gray-scale method.Results:The mean values of nine items of neonates brain were obtained,the whole brain volume was(419.15 ±5.33)cm3,the volume of the left cerebral hemisphere was(187.62 ±2.91)cm3,the right cerebral hemisphere volume was(187.61 ±3.38)cm3,the volume of the left cerebellar hemisphere was(17.15 ±1.05)cm3,the right cerebellar hemisphere volume was(16.99 ±0.85)cm3,the left lateral ventricle volume was(3.76 ±0.07)cm3,the right lateral ventricle volume was(3.75 ±0.08)cm3,the third ventricle volume was(0.22 ±0.01)cm3,the fourth ventricle volume was(0.24 ±0.01)cm3,and there was no statistically significant differences in comparison between the volume of the left and right cerebral hemisphere,the left and right cerebellar hemisphere,the left and right lateral ventricle(P0.05).Conclusion:MSCT is accurate and reliable in vivo measurement of the normal neonatal brain volume,so it can recognize the CT anatomy of normal neonatal brain from imaging perspective.
Key concepts: Cerebellar hemisphere, Ventricle, Medicine, Volume (thermodynamics), Brain size, Anatomy, Cerebral ventricle, Cerebellum