Fracture analysis of frictional steel rail

Liu Li

Open publisher page 0 citations

Abstract

The failure of the rail was analyzed by optical microscope,SEM and micro-hardness testing method.The result showed that it was caused by the high hardness martensite produced after the rail absorbed,the frictional heat which could be occurred when the rail severely straightened or hitted.

About this research paper

What this paper is about

The failure of the rail was analyzed by optical microscope,SEM and micro-hardness testing method.The result showed that it was caused by the high hardness martensite produced after the rail absorbed,the frictional heat which could be occurred when the rail severely straightened or hitted.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The failure of the rail was analyzed by optical microscope,SEM and micro-hardness testing method.The result showed that it was caused by the high hardness martensite produced after the rail absorbed,the frictional heat which could be occurred when the rail severely straightened or hitted.

Key concepts: Materials science, Martensite, Fracture (geology), Optical microscope, Composite material, Forensic engineering, Metallurgy, Indentation hardness