2013•Journal of North China Electric Power UniversityRequires access

Simulation analysis of cooling tower inlet height

Yang Zhou

Open publisher page 0 citations

Abstract

Based on the heat and mass transfer theories of air-water flow,a three-dimensional calculation model for a 20 000 m2spray area cooling tower of a AP1000 nuclear power plant was established with Fluent numerical software.Different values of the height of the air inlet were simulated and calculated,and the influences of different crosswinds on the flow field,outlet water temperature and inlet air quantity were analyzed.The air inlet height structure design of 210 meters high tower was optimized.

About this research paper

What this paper is about

Based on the heat and mass transfer theories of air-water flow,a three-dimensional calculation model for a 20 000 m2spray area cooling tower of a AP1000 nuclear power plant was established with Fluent numerical software.Different values of the height of the air inlet were simulated and calculated,and the influences of different crosswinds on the flow field,outlet water temperature and inlet air quantity were analyzed.The air inlet height structure design of 210 meters high tower was optimized.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Based on the heat and mass transfer theories of air-water flow,a three-dimensional calculation model for a 20 000 m2spray area cooling tower of a AP1000 nuclear power plant was established with Fluent numerical software.Different values of the height of the air inlet were simulated and calculated,and the influences of different crosswinds on the flow field,outlet water temperature and inlet air quantity were analyzed.The air inlet height structure design of 210 meters high tower was optimized.

Key concepts: Inlet, Cooling tower, Fluent, Crosswind, Tower, Environmental science, Computational fluid dynamics, Marine engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Simulation analysis of cooling tower inlet height — Research Paper | ScholarLens