Numerical Simulation on Effect of Cross-wind to Cooling Tower of 300MW Thermal Power Unit

Liu Jian-ta

Open publisher page 0 citations

Abstract

Taking a hyperbolic natural draft cooling tower of 300 MW thermal power unit as research object,effect of crosswind to cooling tower performance and air inlet velocity field are analyzed. These researches of numerical simulation are based on the Fluent Software. Researches show that cooling temperature difference will decrease first and then increase,outlet temperature of the tower will increase and then decrease with the increasing of cross-wind velocity. Air inlet velocity field of the cooling tower will be disturbed by the existence of the cross-wind,of which the critical wind speed is 6m /s.

About this research paper

What this paper is about

Taking a hyperbolic natural draft cooling tower of 300 MW thermal power unit as research object,effect of crosswind to cooling tower performance and air inlet velocity field are analyzed. These researches of numerical simulation are based on the Fluent Software. Researches show that cooling temperature difference will decrease first and then increase,outlet temperature of the tower will increase and then decrease with the increasing of cross-wind velocity. Air inlet velocity field of the cooling tower will be disturbed by the existence of the cross-wind,of which the critical wind speed is 6m /s.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Taking a hyperbolic natural draft cooling tower of 300 MW thermal power unit as research object,effect of crosswind to cooling tower performance and air inlet velocity field are analyzed. These researches of numerical simulation are based on the Fluent Software. Researches show that cooling temperature difference will decrease first and then increase,outlet temperature of the tower will increase and then decrease with the increasing of cross-wind velocity. Air inlet velocity field of the cooling tower will be disturbed by the existence of the cross-wind,of which the critical wind speed is 6m /s.

Key concepts: Crosswind, Fluent, Cooling tower, Tower, Wind speed, Engineering, Marine engineering, Inlet