2013Unpublished venueRequires access

Determination of Tin Content in Cadmium by Hydride Generation-Atomic Fluorescence Spectrometry

Shufang Tang

Open publisher page 0 citations

Abstract

A method for the determination of tin in cadmium by hydride generation-atomic fluorescence spectrometry was proposed.The interference effect of cadmium matrix on tin determination and the interference elimination method was studied.The conditions for sample digestion and hydride generation were optimized.The detection limit for tin is 0.08 mg/kg and the recovery is 99.0%~104.0%.The method is accurate,reliable,and was used for routine analysis of samples with good results.

About this research paper

What this paper is about

A method for the determination of tin in cadmium by hydride generation-atomic fluorescence spectrometry was proposed.The interference effect of cadmium matrix on tin determination and the interference elimination method was studied.The conditions for sample digestion and hydride generation were optimized.The detection limit for tin is 0.08 mg/kg and the recovery is 99.0%~104.0%.The method is accurate,reliable,and was used for routine analysis of samples with good results.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method for the determination of tin in cadmium by hydride generation-atomic fluorescence spectrometry was proposed.The interference effect of cadmium matrix on tin determination and the interference elimination method was studied.The conditions for sample digestion and hydride generation were optimized.The detection limit for tin is 0.08 mg/kg and the recovery is 99.0%~104.0%.The method is accurate,reliable,and was used for routine analysis of samples with good results.

Key concepts: Tin, Hydride, Cadmium, Detection limit, Chemistry, Mass spectrometry, Analytical Chemistry (journal), Matrix (chemical analysis)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Tin Content in Cadmium by Hydride Generation-Atomic Fluorescence Spectrometry — Research Paper | ScholarLens