2012Shiyong yaowu yu linchuangRequires access

Determination of metronidazole in metronidazole cream by HPLC

Tang Xin-qiang

Open publisher page 0 citations

Abstract

Objective To establish an HPLC method for determining the metronidazole in metronidazole cream.Methods The analytical column was Hypersil BDS-C18(250 mm×4.6 mm,5 μm),the mobile phase was methanol-water(20∶ 80)at the flow rate of 1.0 mL/min at 30 ℃.Detection wavelength was set at 320 nm,and the incoming sample amount was 20 μL.Results The linear range of metronidazole was 5.02~40.16 μg/mL,r=0.999 9,the average recovery rate(n=9)was 98.2%,RSD was 2.5%.Conclusion This method is accurate and reliable,it can be used for the quality control of metronidazole cream.

About this research paper

What this paper is about

Objective To establish an HPLC method for determining the metronidazole in metronidazole cream.Methods The analytical column was Hypersil BDS-C18(250 mm×4.6 mm,5 μm),the mobile phase was methanol-water(20∶ 80)at the flow rate of 1.0 mL/min at 30 ℃.Detection wavelength was set at 320 nm,and the incoming sample amount was 20 μL.Results The linear range of metronidazole was 5.02~40.16 μg/mL,r=0.999 9,the average recovery rate(n=9)was 98.2%,RSD was 2.5%.Conclusion This method is accurate and reliable,it can be used for the quality control of metronidazole cream.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish an HPLC method for determining the metronidazole in metronidazole cream.Methods The analytical column was Hypersil BDS-C18(250 mm×4.6 mm,5 μm),the mobile phase was methanol-water(20∶ 80)at the flow rate of 1.0 mL/min at 30 ℃.Detection wavelength was set at 320 nm,and the incoming sample amount was 20 μL.Results The linear range of metronidazole was 5.02~40.16 μg/mL,r=0.999 9,the average recovery rate(n=9)was 98.2%,RSD was 2.5%.Conclusion This method is accurate and reliable,it can be used for the quality control of metronidazole cream.

Key concepts: Metronidazole, Chromatography, High-performance liquid chromatography, Chemistry, Antibiotics, Biochemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of metronidazole in metronidazole cream by HPLC — Research Paper | ScholarLens