2005Zhongguo fuyou baojianRequires access

Analysis of the internal quality control results of testing TSH in dried blood spots by TRFIA

Qin Liang

Open publisher page 0 citations

Abstract

Objective:To explore the quality control of using TRFIA to test TSH in dried blood spots.Methods:Performing the statistical indicators(x,P50,SD,CV,max,min,etc)analysis to TSH in dried blood spots of quality control in a year;testing TSH in the different parts of blood spots simultaneously.Results:The testing indicators(x,P50) of TSH in dried spots of quality control both were in the ±20 range of the standard value(true value),the CV of C_1,C_2 were separately in 6.6%~11.7%,3.6~15.5%;the TSH testing value was in the 1/2 point of blood spots from center to side approached to the true value.Conclusions:The precision of the TSH testing value in dried blood spots tested by TRFIA to screen newborn Congenital Hypothroidism(CH)is high and the quality can be controlled effectively.

About this research paper

What this paper is about

Objective:To explore the quality control of using TRFIA to test TSH in dried blood spots.Methods:Performing the statistical indicators(x,P50,SD,CV,max,min,etc)analysis to TSH in dried blood spots of quality control in a year;testing TSH in the different parts of blood spots simultaneously.Results:The testing indicators(x,P50) of TSH in dried spots of quality control both were in the ±20 range of the standard value(true value),the CV of C_1,C_2 were separately in 6.6%~11.7%,3.6~15.5%;the TSH testing value was in the 1/2 point of blood spots from center to side approached to the true value.Conclusions:The precision of the TSH testing value in dried blood spots tested by TRFIA to screen newborn Congenital Hypothroidism(CH)is high and the quality can be controlled effectively.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To explore the quality control of using TRFIA to test TSH in dried blood spots.Methods:Performing the statistical indicators(x,P50,SD,CV,max,min,etc)analysis to TSH in dried blood spots of quality control in a year;testing TSH in the different parts of blood spots simultaneously.Results:The testing indicators(x,P50) of TSH in dried spots of quality control both were in the ±20 range of the standard value(true value),the CV of C_1,C_2 were separately in 6.6%~11.7%,3.6~15.5%;the TSH testing value was in the 1/2 point of blood spots from center to side approached to the true value.Conclusions:The precision of the TSH testing value in dried blood spots tested by TRFIA to screen newborn Congenital Hypothroidism(CH)is high and the quality can be controlled effectively.

Key concepts: Spots, Medicine, Dried blood, Blood testing, Quality (philosophy), Internal medicine, Chromatography, Pathology

Related papers

Back to paper searchBrowse research topicsOriginal source
Analysis of the internal quality control results of testing TSH in dried blood spots by TRFIA — Research Paper | ScholarLens