2011•Gaoya dianqiRequires access

Study on the Response Characteristic of the Resistor Divider for Impulse Voltage Mearsurement

Ding Weidong

Open publisher page 0 citations

Abstract

A 500 kV precision resistor divider for impulse voltage measurement is developed,which can be used for measuring full wave and front-chopped impulse voltage.The divider is simulated through ATP,of which the response characteristic is tested by using a step voltage source.The influencing factors on the response characteristic of the divider are studied,such as damping resistance,high voltage arm's resistance and height above ground.The partial response time of the divider is 7.4 ns,and the overshoot is 18.8 %.

About this research paper

What this paper is about

A 500 kV precision resistor divider for impulse voltage measurement is developed,which can be used for measuring full wave and front-chopped impulse voltage.The divider is simulated through ATP,of which the response characteristic is tested by using a step voltage source.The influencing factors on the response characteristic of the divider are studied,such as damping resistance,high voltage arm's resistance and height above ground.The partial response time of the divider is 7.4 ns,and the overshoot is 18.8 %.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A 500 kV precision resistor divider for impulse voltage measurement is developed,which can be used for measuring full wave and front-chopped impulse voltage.The divider is simulated through ATP,of which the response characteristic is tested by using a step voltage source.The influencing factors on the response characteristic of the divider are studied,such as damping resistance,high voltage arm's resistance and height above ground.The partial response time of the divider is 7.4 ns,and the overshoot is 18.8 %.

Key concepts: Voltage divider, Current divider, Resistor, Impulse (physics), Voltage, Frequency divider, Electrical engineering, Impulse generator

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on the Response Characteristic of the Resistor Divider for Impulse Voltage Mearsurement — Research Paper | ScholarLens