1993•IEEJ Transactions on Power and EnergyOpen access

Response Characteristics of Resistive Voltage Divider for Impulse Voltage Measurement

Yoshihiro Kawaguchi, Hiroshi Murase, Hiroshi Koyama

Open full text 0 citations

Abstract

International Standard in high voltage measurement handled by IEC Pub. 60-3 (1976) has been pointed out that its requirement is not sufficient in the impulse voltage measurement accuracy, especially in front-chopped impulse.And its revisory work has been executed by IEC Technical Committee. Corresponding to this work, the unit step response of a resistive voltage divider is discussed by the comparison of the measurement with the calculation by EMTP, to establish the simulation procedure by EMTP, in this paper.Then, this EMTP simulation is utilized for the calculation of measured voltage in the virtual impulse voltage tests (full and front-chopped), and the measurement accuracy is discussed taking into account of various time parameters of measuring system, to help understanding of the revision.

Open-access reader

About this research paper

What this paper is about

International Standard in high voltage measurement handled by IEC Pub. 60-3 (1976) has been pointed out that its requirement is not sufficient in the impulse voltage measurement accuracy, especially in front-chopped impulse.And its revisory work has been executed by IEC Technical Committee. Corresponding to this work, the unit step response of a resistive voltage divider is discussed by the comparison of the measurement with the calculation by EMTP, to establish the simulation procedure by EMTP, in this paper.Then, this EMTP simulation is utilized for the calculation of measured voltage in the virtual impulse voltage tests (full and front-chopped), and the measurement accuracy is discussed taking into account of various time parameters of measuring system, to help understanding of the revision.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

International Standard in high voltage measurement handled by IEC Pub. 60-3 (1976) has been pointed out that its requirement is not sufficient in the impulse voltage measurement accuracy, especially in front-chopped impulse.And its revisory work has been executed by IEC Technical Committee. Corresponding to this work, the unit step response of a resistive voltage divider is discussed by the comparison of the measurement with the calculation by EMTP, to establish the simulation procedure by EMTP, in this paper.Then, this EMTP simulation is utilized for the calculation of measured voltage in the virtual impulse voltage tests (full and front-chopped), and the measurement accuracy is discussed taking into account of various time parameters of measuring system, to help understanding of the revision.

Key concepts: Emtp, Impulse (physics), Voltage, Voltage divider, Resistive touchscreen, Electrical engineering, Impulse generator, Electronic engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Response Characteristics of Resistive Voltage Divider for Impulse Voltage Measurement — Research Paper | ScholarLens