Feasibility of multislice CT angiography of pulmonary artery with high concentration and low dose contrast media
Cheng Liu
Abstract
Cheng Liu
Abstract
Objective:To study the feasibility of multislice CT angiography of pulmonary artery with high concentration and low dose contrast media.Methods:Forty patients with chest dynamic enhanced using multislice CT body-perfusion protocol were divided into 2 groups according to the kind and dosage of contrast media as follows: Group A,300 mgI/ml contrast media 100 ml and saline 30 ml;Group B,400 mgI/ml contrast media 60 ml and saline 30 ml.Injected rate was 4 ml/s.The time-density curve(TDC) of the trunk of pulmonary artery was delineated.The time to peak,peak contrast enhancement,the time of begin to 200 HU(Tb200) and the time of duration on 200HU(T200) were recorded.Results:As for the time to peak and peak contrast enhancement of the trunk of pulmonary artery,group B was earlier and higher than group A.The T200 and Tb200 had significant difference between the two groups.Conclusion:It is feasible to use high concentration and low dose contrast media for multislice CT pulmonary artery angiography.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective:To study the feasibility of multislice CT angiography of pulmonary artery with high concentration and low dose contrast media.Methods:Forty patients with chest dynamic enhanced using multislice CT body-perfusion protocol were divided into 2 groups according to the kind and dosage of contrast media as follows: Group A,300 mgI/ml contrast media 100 ml and saline 30 ml;Group B,400 mgI/ml contrast media 60 ml and saline 30 ml.Injected rate was 4 ml/s.The time-density curve(TDC) of the trunk of pulmonary artery was delineated.The time to peak,peak contrast enhancement,the time of begin to 200 HU(Tb200) and the time of duration on 200HU(T200) were recorded.Results:As for the time to peak and peak contrast enhancement of the trunk of pulmonary artery,group B was earlier and higher than group A.The T200 and Tb200 had significant difference between the two groups.Conclusion:It is feasible to use high concentration and low dose contrast media for multislice CT pulmonary artery angiography.
Key concepts: Medicine, Multislice, Contrast medium, Pulmonary artery, Saline, Perfusion, Angiography, Contrast (vision)