2011Rock and Mineral AnalysisRequires access

Determination of Selenium in Biological Samples by Hydride Generation Atomic Fluorescence Spectrometry

Wang Yu-lin

Open publisher page 0 citations

Abstract

A method for determination of selenium in biological samples by hydride generation-atomic fluorescence spectrometry was developed.The samples were decomposed with HNO3-HClO4 and Fe3+ was used as relieving reagent in 4 mol/L HCl medium.The detection limit of the method was 0.02 μg/L.The method has been applied to the determination of selenium in biological national standard reference materials and the results are in agreement with certified values with precision of 1.51% RSD(n=11).

About this research paper

What this paper is about

A method for determination of selenium in biological samples by hydride generation-atomic fluorescence spectrometry was developed.The samples were decomposed with HNO3-HClO4 and Fe3+ was used as relieving reagent in 4 mol/L HCl medium.The detection limit of the method was 0.02 μg/L.The method has been applied to the determination of selenium in biological national standard reference materials and the results are in agreement with certified values with precision of 1.51% RSD(n=11).

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method for determination of selenium in biological samples by hydride generation-atomic fluorescence spectrometry was developed.The samples were decomposed with HNO3-HClO4 and Fe3+ was used as relieving reagent in 4 mol/L HCl medium.The detection limit of the method was 0.02 μg/L.The method has been applied to the determination of selenium in biological national standard reference materials and the results are in agreement with certified values with precision of 1.51% RSD(n=11).

Key concepts: Selenium, Hydride, Certified reference materials, Chemistry, Detection limit, Reagent, Mass spectrometry, Fluorescence spectrometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Selenium in Biological Samples by Hydride Generation Atomic Fluorescence Spectrometry — Research Paper | ScholarLens