2005Chinese Journal of NeuromedicineRequires access

Transcutaneous endovascular placement of self-expandable stent in the treatment of carotid artery stenosis: report of nine cases

Wang Xing-che

Open publisher page 0 citations

Abstract

Objective To introduce the procedure of carotid stenting, and to investigate the effectiveness, safety, and practicability of carotid stenting for carotid artery stenosis. Methods From January, 2004 to June, 2005, 9 patients (3 women and 6 men; mean age, 65.4 years; age range, 45~75 years) with symptomatic internal carotid artery stenosis (≥70% according to the NASCET), underwent 11 extracranial carotid angioplasty and stenting (CAS) procedures with the self-expanding stents. Cerebral protection device was furnished for all patients. Antiplatelet therapy and cerebral angiography as well as cervical Doppler sonography were performed perioperatively, followed by clinical follow-up of 5.5 months (1~12). Results Extracranial CAS was successful in all patients, with average residual stenosis of less than 20%. There were no deaths. Asymptomatic cerebral infarction was found in 1 case, hypotension and bradycardia in 2 cases that required continuous intravenous medication and inotropic support for 24 h. Conclusion Carotid stenting is considered to be a feasible and safe procedure for the treatment of carotid artery stenosis.

About this research paper

What this paper is about

Objective To introduce the procedure of carotid stenting, and to investigate the effectiveness, safety, and practicability of carotid stenting for carotid artery stenosis. Methods From January, 2004 to June, 2005, 9 patients (3 women and 6 men; mean age, 65.4 years; age range, 45~75 years) with symptomatic internal carotid artery stenosis (≥70% according to the NASCET), underwent 11 extracranial carotid angioplasty and stenting (CAS) procedures with the self-expanding stents. Cerebral protection device was furnished for all patients. Antiplatelet therapy and cerebral angiography as well as cervical Doppler sonography were performed perioperatively, followed by clinical follow-up of 5.5 months (1~12). Results Extracranial CAS was successful in all patients, with average residual stenosis of less than 20%. There were no deaths. Asymptomatic cerebral infarction was found in 1 case, hypotension and bradycardia in 2 cases that required continuous intravenous medication and inotropic support for 24 h. Conclusion Carotid stenting is considered to be a feasible and safe procedure for the treatment of carotid artery stenosis.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To introduce the procedure of carotid stenting, and to investigate the effectiveness, safety, and practicability of carotid stenting for carotid artery stenosis. Methods From January, 2004 to June, 2005, 9 patients (3 women and 6 men; mean age, 65.4 years; age range, 45~75 years) with symptomatic internal carotid artery stenosis (≥70% according to the NASCET), underwent 11 extracranial carotid angioplasty and stenting (CAS) procedures with the self-expanding stents. Cerebral protection device was furnished for all patients. Antiplatelet therapy and cerebral angiography as well as cervical Doppler sonography were performed perioperatively, followed by clinical follow-up of 5.5 months (1~12). Results Extracranial CAS was successful in all patients, with average residual stenosis of less than 20%. There were no deaths. Asymptomatic cerebral infarction was found in 1 case, hypotension and bradycardia in 2 cases that required continuous intravenous medication and inotropic support for 24 h. Conclusion Carotid stenting is considered to be a feasible and safe procedure for the treatment of carotid artery stenosis.

Key concepts: Medicine, Stenosis, Asymptomatic, Carotid stenting, Internal carotid artery, Angioplasty, Stent, Carotid arteries

Related papers

Back to paper searchBrowse research topicsOriginal source
Transcutaneous endovascular placement of self-expandable stent in the treatment of carotid artery stenosis: report of nine cases — Research Paper | ScholarLens